IBA ibaDeskline SAS Manual Download Page 1

 
 
 

 

ibaDeskline SAS 

iba Industrial Computer 

 

Manual 

Issue 1.3 

Summary of Contents for ibaDeskline SAS

Page 1: ...ibaDeskline SAS iba Industrial Computer Manual Issue 1 3...

Page 2: ...ull compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be down loaded on the Internet...

Page 3: ...5 Error monitoring 17 5 5 1 ibaOut Temp 18 5 5 2 ibaOut State 19 6 Installation connection and first switching on 20 6 1 Safety instructions 20 6 2 Setting up 20 6 3 Connection and first switching on...

Page 4: ...2 2 Select the language 32 9 2 3 Enter the product key 32 9 2 4 Partitioning 33 9 2 5 Completing installation 37 9 3 Windows Updates 38 9 4 Antivirus Software 38 9 5 Installing iba software 38 10 Dev...

Page 5: ...if he she is capable of assessing safety and recognizing possible consequences and risks on the basis of his her specialist train ing knowledge and experience and knowledge of the standard regulations...

Page 6: ...rol function The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of inju...

Page 7: ...aphic card there is an additional DVI VGA adapter cable ibaSoftware license key when a software was ordered The documentation contains Manual Subcontractors documentation Software Operating system Win...

Page 8: ...ks 1 redundant power supply unit The net volume corresponds to the volume of approx 6 hard disks with simultane ous high performance and system stability against failure Server system with Windows Ser...

Page 9: ...t for several minutes until the com ponents have cooled down Thus you will avoid injuries due to the electric shock or burns Connect the device to one supply voltage only according to specifications o...

Page 10: ...Manual ibaDeskline SAS 10 Issue 1 3 5 Description 5 1 Front view ibaDeskline ibaDeskline PCI Optical drive with integrated writing function Plug in slots for hard disks...

Page 11: ...view ibaDeskline 1 USB 2 0 interfaces 2 USB 3 0 interfaces 3 Headset interface 4 Microphone interface 5 Power button 6 Reset button ibaDeskline PCI 1 2 USB 2 0 interfaces 3 Headset interface 4 Microph...

Page 12: ...tandard system version ibaDeskline Connections for external devices keyboard mouse network etc Slots X21 to X26 for low profile iba cards Slot X2 for hard disk controller Slots X3 to X7 PCIe Power sup...

Page 13: ...ions for external devices keyboard mouse network etc Slots X21 to X26 for low profile iba cards Slot X1 for hard disk controller Slots X2 X4 to X7 PCI whereas X3 PCIe for special graphic card Power su...

Page 14: ...supply unit ibaDeskline is shown as example below Connections for external devices keyboard mouse network etc Slots X21 to X26 for low profile iba cards e g output connections of FOB 4i cards Slot X2...

Page 15: ...SAS Manual Issue 1 3 15 5 4 Internal view ibaDeskline Power supply unit redundant for RAID systems PCIe slots Hard disk controller Slots for low profile iba cards Drive bracket Fan 12 cm Internal USB...

Page 16: ...SAS 16 Issue 1 3 ibaDeskline PCI Power supply unit redundant for RAID systems PCI slots Special graphic card optional Hard disk controller Slots for low profile iba cards Drive bracket Fan 12 cm Inter...

Page 17: ...it is installed by default in slot X21 Note The subsequent installation of a card is carried out according to the installation in an ibaRackline computer Please refer to the ibaRackline manual The st...

Page 18: ...open Power OK temperature OK open open Power OK overtemperature open closed Contact loading capacity Nominal current 400 mA Nominal voltage 60 V Compatibility to previous models ibaDeskline computers...

Page 19: ...or Power error and overtemperature Power error temperature OK Power OK overtemperature Contact loading capacity Nominal current 300 mA Nominal voltage 220 V DC Compatibility to previous ibaRackline m...

Page 20: ...ice only to earthed power networks TN networks according to VDE 0100 Part 300 or IEC 60364 3 The operation via ungrounded networks or networks IT networks earthed via imped ance is not permitted Never...

Page 21: ...The device is delivered in a pre installed and configured state You can find the parameters of the operating system and ibaSoftware in the corresponding manuals or in the Online Help 1 Connect the de...

Page 22: ...the housing Electrostatic discharge Touch the components only in electrostatically discharged state Note If you upgrade the device observe the instructions in the subcontractors documenta tion Back up...

Page 23: ...ns ex factory ibaDeskline ibaDeskline PCI 1x analog VGA 2x digital DVI HDMI 1x analog VGA Note If you want to use an additional monitor with ibaDeskline PCI it is necessary to install an additional sp...

Page 24: ...graphic card with a bus interface PCI Express x1 The slot supports only this interface version Special graphic card Chip set NVIDIA Quadro nView Enabled Yes Bus Interface PCI Express x1 Max Displays...

Page 25: ...Carry out the maintenance work 7 Attach the side panels again 8 Put the device into operation again 8 2 Power supply slide in module for replacement of redundant power supply unit If the green lamp o...

Page 26: ...ge Touch the components only in electrostatically discharged state Important Note The RAID system is not automatically restored after having changed the hard disk Use the program Adaptec Storage Manag...

Page 27: ...The defective hard disk is not indicated 4 Mark the hard disk which is available Device 1 in the example above and click on the Locate icon in the Physical device section The available hard disk blin...

Page 28: ...t the hard disk has not been registered in the system 7 Mark the new hard disk Device 2 in the example above and click on the Initialize icon in the Physical Device section 8 Then click on the Spare M...

Page 29: ...ibaDeskline SAS Manual Issue 1 3 29 10 Confirm the following overview with Finish 11 The following message appears when the operation was successful Otherwise an error message appears...

Page 30: ...anual ibaDeskline SAS 30 Issue 1 3 12 The progress of the rebuild process is displayed under Tasks 13 As soon as the hard disk has been successfully registered in the system the pro gram can be closed...

Page 31: ...lled Do not change the basic configuration of the device components e g motherboard If you modify the device components it can make installation with the Recovery DVD impossible 9 2 Installing Windows...

Page 32: ...a black or green screen is visible during the process 9 2 2 Select the language When the installation has started you can select the system language to be installed When using Windows Embedded Standar...

Page 33: ...m with No 9 2 4 Partitioning There are several possibilities to set up partitions Set up a new drive completey as system drive Set up partitions on a new drive Install an operating system on a drive a...

Page 34: ...hapter 9 2 5 Completing installation Possibility 2 Partitioning the new drive You use a new drive and want to set up partitions 1 Click Drive Options advanced 2 Click New 3 Enter the partition size 4...

Page 35: ...nt to install the operating system 1 Click Drive Options advanced 2 Mark the system partition 3 Click Format 4 Confirm with OK 5 Mark the primary partition normally the smaller one 6 Click Format 7 Co...

Page 36: ...hapter 9 2 5 Completing installation Possibility 5 Substitute Windows Embedded Standard 7 with Windows 2008 The drive is already in use and you want to replace the operating system 1 Click Drive Optio...

Page 37: ...ions advanced 2 Mark the primary partition normally the smaller one 3 Click Delete 4 Confirm with OK 5 Mark the unpartitioned space 6 Click Next and continue with chapter 9 2 5 Completing installation...

Page 38: ...in your company Consult your IT depart ment if necessary 9 4 Antivirus Software There is no antivirus software installed on iba systems in delivery state Please install the antivirus software package...

Page 39: ...ibaDeskline SAS Manual Issue 1 3 39 10 Device dimensions dimensions in mm...

Page 40: ...F no condensation Protection class IP20 Power supply ibaDeskline SAS standard 90 V to 264 V AC 110 V to 374 V DC 8 A 4 A 47 Hz to 63 Hz Power output ibaDeskline SAS standard Max 400 W ibaDeskline SAS...

Page 41: ...memory 8 GB DDR3 RAM 8 GB DDR2 RAM Slots PCI Express x16 for SAS RAID con troller 5x PCI Express for iba measuring cards PCI Express x16 for SAS RAID con troller PCI Express 4x for special graphics c...

Page 42: ...1 hard disk 1 redundant power sup ply unit Upgrade kit to RAID 6 system 1 controller 7 hard disks 1 redundant power sup ply unit HD 300 GB to 600 GB Upgrade SAS HD 300 GB to 900 GB Upgrade SAS On req...

Page 43: ...serial number iba S N of the product Contact Headquarters iba AG Postbox 1828 DE 90708 F rth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Contact Harald Opel Shipping address...