background image

Page 1                                                                      2019-05-10                                                      [email protected]

 

 

 

LifePO4 MkIII pure battery power supply user

’s guide 

By Ian Jin, May 15, 2020 Ver. 1.01b (Draft) 

A.  Safety warnings (please read first)   

LifePO4 battery cells are high density energy storage devices. They could have risk of leaking, overheating, smoke, 

fire, explosion or damaging the circuit board if don't use properly.  

1. Never short circuit at any time during storage, assembling and operation. 

2. All battery cells are internally connected together in parallel on the PCB. You must never reverse the positive and 

negative terminals when assemble/solder them into PCB. Reversing battery terminals could be very dangerous.  

3. Have to wearing protection glasses, gloves and other safety equipment when assemble/disassemble batteries. 

4. Never expose battery and the battery power supply board under high temperature, sunshine or water. 

5. In case of any issue happens, please put batteries or battery power supply board in a fire proof container. Also 

has to make sure the power adapter is disconnected.  

6. Please follow other common battery safety instructions. 

7. Have to use 

80W or higher power iron

 to solder battery holders, batteries or connectors to the board. 

8. It is your responsibility to ensure the safety of DIY activities. 

 

B.  Introduction 

Battery is a kind of passive power supply without any feedback. Comparing with active power supply such as a 

voltage regulator, it has much better load transient response and less noise. This LifePO4 pure battery power 

supply is a completed solution to provide battery based clean power voltage rails to DAC and other sensitive audio 

applications.   

 

C.  Highlighted Features and Specifications 

 

Five independent voltage rails 

Two 3.3V LifePO4 battery direct isolated voltage rails for clock and DAC section. 

Two 3.3V-13.2V battery direct isolated voltage rails for analog section and other sensitive circuits. Each of 

the rails can be configured as 3.3V, 6.6V, 9.9V or 13.2V separately. 

Additional 5V 2A linear LT3042 regulated DC output for digital section (non-isolated, can be 

enabled/disabled). 

Summary of Contents for LifePO4 MkIII

Page 1: ...er supply board in a fire proof container Also has to make sure the power adapter is disconnected 6 Please follow other common battery safety instructions 7 Have to use 80W or higher power iron to sol...

Page 2: ...panel Programmable screensaver function to protect OLED from screen burn in Can use either 26650 battery cells with tabs or standard 26650 battery holders D LifePO4 MkIII new improvements Ready for up...

Page 3: ...Page 3 2019 05 10 iancanada mail gmail com...

Page 4: ...or battery holders to BT1 BT2 BT3 BT4 BT5 BT8 BT9 and BT10 or configure battery cells accord to the required voltages Jumper wires may also be required Please refer to battery configuration section f...

Page 5: ...nected to J5 J1 3 3V pure battery output voltage rail in 2 pin 5 0mm terminal This output is galvanic isolated from all other output and input It comes with over current and over discharge protections...

Page 6: ...r normal digital sections before isolator It s not recommended for sensitive audio circuits like DAC clock and I V stage This output is not galvanic isolated from DC input This output can be disabled...

Page 7: ...All other pins reserved please keep un connected 9600 N 8 1 J13 Micro USB socket reserved for future applications or FW upgrade J30 5V output to UcMateConditioner Internally connected to J8 J29 ON OFF...

Page 8: ...BT10 BT9 TP7 TP8 short 6 6V BT2 BT10 TP9 TP10 short 3 3V BT2 TP11 TP12 short 0V Non Non BT5 BT4 BT3 BT1 26650 LifePO4 battery cells can be configured for voltage rail at J3 Output voltage Battery cell...

Page 9: ...sabled into standby mode when this voltage is reached 3 25V to 3 75V Default 3 35V 3 5V To enable continuous disable the 5V linear voltage rail EN enabled or CON continuous or DIS disabled Default is...

Page 10: ...or more than 2 seconds 3 Extern on off control signal changing from 0V to 3 3V 6V will turn on the power 2 How to turn off the power supply There are 3 ways to turn on the power supply 1 Press and hol...

Page 11: ...oard with the main PCB through the supplied 10 pin FFC cable from J9 to J14 Please see the picture Connection between main PCB and external OLED board for the orientation of cable Reversing the FFC FP...

Page 12: ...mes may fall into audible frequency range though it still fully functional To fix this issue you can just simply replace it with a higher voltage power supply say a standard 18 5V laptop adapter or hi...

Page 13: ...Page 13 2019 05 10 iancanada mail gmail com 1 LifePO4 MkIII power supply 2 LifePO4 MkIII power supply with battery holders and batteries...

Page 14: ...Page 14 2019 05 10 iancanada mail gmail com 3 Upgrade to ultra capacitor power supply by UcMateConditioer UcHybrid and UcAdpater 4 LifePO4 power supply integrates with DAC system...

Page 15: ...er supply is the property of Ian Jin You are granted a non exclusive non transferable non sublicenseable royalty free right to use the LifePO4 MkIII battery power supply board solely for your own non...

Reviews: