Chapter 1 Specifications Check
1.3 Electrical Specifications
66
1.3.4 Extension I/O Input and Output Interface
Input Section
Output Section
Input Points
16 points
Output Points
16 points
Input Voltage
24V DC ±10%
Load Voltage
24V DC ±10%
Input Current
4mA / per output
ON Min. 18V DC
ON/OFF
Voltage
OFF Max. 6V DC
Load Current
50mA/1 per circuit
Ty
pe
Insulation Type
Photocoupler
Insulation
Insulation Type
Photocoupler
Insulation
NPN
Load
External Power
Source
24V DC +10%
Int
erna
l P
ow
er
Output Terminal
PNP
Note 1: The maximum load current total becomes 400mA for every 8 ports from Output Port No. 316.
(Maximum in every point is 100mA)
External Power
Source
24V DC +10%
Load
Output Terminal
Int
erna
l P
ow
er
Summary of Contents for TTA Series
Page 1: ...Tabletop Robot TTA Instruction Manual 12th Edition IAI Corporation ...
Page 2: ......
Page 4: ......
Page 23: ...13 ...
Page 24: ...14 ...
Page 25: ...15 ...
Page 42: ...32 ...
Page 134: ...124 Chapter 3 Wiring 3 4 Wiring Method ...
Page 164: ...Chapter 4 Operation 4 8 Payload Adjusted for Setting Values 154 ...
Page 280: ...Chapter 7 Appendix 7 2 Extension SIO Features 270 ...
Page 312: ...Chapter 8 Maintenance and Inspection 8 7 Period of Time for Fan Unit Replacement 302 ...
Page 368: ...Chapter 9 External Dimensions 9 3 Option 358 ...
Page 370: ...Chapter 10 Life 360 ...
Page 377: ......