114
3.3.5
Extension I/O
The device mounted in an extension slot (two slots) can be assigned to the general-purposed input
048 to 299 and general-purposed output 348 to 599.
0V
BR- 1
1A
P24
OUT0
1B
BR- 3
RD- 1
2A
P24
OUT1
2B
RD- 3
Universal Input Port 048
OR- 1
3A
IN0
OUT2
3B
OR- 3
Universal Output Port 348
Universal Input Port 049
YW- 1
4A
IN1
OUT3
4B
YW- 3
Universal Output Port 349
Universal Input Port 050
GN- 1
5A
IN2
OUT4
5B
GN- 3
Universal Output Port 350
Universal Input Port
BL- 1
6A
IN3
OUT5
6B
BL- 3
Universal Output Port
Universal Input Port
PL- 1
7A
IN4
OUT6
7B
PL- 3
Universal Output Port
Universal Input Port
GY- 1
8A
IN5
OUT7
8B
GY- 3
Universal Output Port
Universal Input Port
WT- 1
9A
IN9
9B
WT- 3
Universal Output Port
Universal Input Port
BK- 1
10A
IN10
OUT9
10B
BK- 3
Universal Output Port
Universal Input Port
BR- 2
11A
IN11
OUT10
11B
BR- 4
Universal Output Port
Universal Input Port
RD- 2
12A
IN12
OUT11
12B
RD- 4
Universal Output Port
Universal Input Port
OR- 2
13A
IN13
OUT12
13B
OR- 4
Universal Output Port
Universal Input Port
YW- 2
14A
IN14
OUT13
14B
YW- 4
Universal Output Port
Universal Input Port
GN- 2
15A
IN15
OUT14
15B
GN- 4
Universal Output Port
BL- 2
16A
16B
BL- 4
Universal Output Port
PL- 2
17A
N
17B
PL- 4
Universal Output Port
GY- 2
18A
N
18B
GY- 4
WT- 2
19A
19B
WT- 4
BK- 2
20A
20B
BK- 4
PIO
Connector
Universal Output Port
Universal Input Port
Universal Input Port
Universal Input Port
IN6
IN7
IN8
OUT8
OUT15
0V(NPN Type)
24V DC(PNP Type)
External
24V DC(NPN Type)
0V(PNP Type)
External
24V DC
External
Use the attached cable for the I/O connection.
Model : CB-PAC-PIO□□□ (□□□ indicates the cable length L. Example. 020
2m)
Flat Cable (20-core)
×
2
20A
20B
1A
1B
Half Pitch MIL Socket
HIF6-40D-1.27R (Hirose Electric)
A
B
L
No treatment
conducted
No treatment
conducted
Chapter 3 Wiring
3.3 IO Circuit
Summary of Contents for TTA Series
Page 1: ...Tabletop Robot TTA Instruction Manual 12th Edition IAI Corporation ...
Page 2: ......
Page 4: ......
Page 23: ...13 ...
Page 24: ...14 ...
Page 25: ...15 ...
Page 42: ...32 ...
Page 134: ...124 Chapter 3 Wiring 3 4 Wiring Method ...
Page 164: ...Chapter 4 Operation 4 8 Payload Adjusted for Setting Values 154 ...
Page 280: ...Chapter 7 Appendix 7 2 Extension SIO Features 270 ...
Page 312: ...Chapter 8 Maintenance and Inspection 8 7 Period of Time for Fan Unit Replacement 302 ...
Page 368: ...Chapter 9 External Dimensions 9 3 Option 358 ...
Page 370: ...Chapter 10 Life 360 ...
Page 377: ......