Configure Trigger, Exposure, and Line Rate Settings
This section describes how to control the exposure time with or without external triggers.
Note:
For the details on the short ASCII commands required to configure the Trigger,
Exposure and Line Rate settings, see "
".
Control via External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
1. Set
Exposure Mode
to
Timed
. (Timed = Default).
2. Specify the Exposure Time in
Exposure Time
.
3. Set
Trigger Mode
to
On
.
4. Configure the
Trigger Source
and
Trigger Activation
settings if necessary.
When Controlling the Exposure Time Using the Pulse Width of the Trigger Input
Signal
1. Set
Trigger Mode
to
On
.
2. Set
Exposure Mode
to
TriggerWidth
. When ExposureMode is set to TriggerWidth,
TriggerMode is automatically set to On.
3. Configure the
Trigger Source
and
Trigger Activation
settings if necessary.
Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
1. Set
Exposure Mode
to
Timed
. (Timed = Default).
2. Set
Trigger Mode
to
Off
. (Off = Default)
3. Specify a line period slower than the exposure time in
Acquisition Line Rate
.
When Not Controlling the Exposure Time
1. Set
Exposure Mode
to
Off
. (Off =Default)
The exposure will be performed with an exposure time equal to 1 / line rate.
Note: