428
Appendi
x
Error List (MAIN application) (In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
200
Encoder parameter data version mismatch warning
The version of encoder parameter data is not supported by this controller. Update the
encoder parameters.
203
Drive-source cutoff relay DET (MELT) error
The drive-source cutoff relay may have fused.
206
Updating system mode error (IAI protocol)
An update command was received other than in the update mode.
207
Update file name error (IAI protocol)
The name of the update program file selected in the update mode is invalid. Select the
correct file and repeat the updating procedure from the beginning.
208
Time data error
The time data is invalid. Check the data.
209
Unsupported control constant table ID error
The control constant table ID is not supported. Check the data.
20A
Control constant table change/query error
The message of the control constant table change/query command contains error.
Check the message that has been sent.
20B
Control constant table write data type specification error
The specified control constant table write data type is invalid. Check the message that
has been sent.
20C
Control constant table management information mismatch error The management information regarding the control constant table is invalid. Confirm
that the control constant table is supported by the controller.
20D
Flash busy reset timeout error
Error erasing/writing the flash ROM
20E
Motorola S-byte count error
The update program file is invalid. Check the file.
20F
Updating target specification error (Received by the
application)
The system application received an updating target specification command. To update
the program, restart the controller and repeat the updating procedure from the
beginning.
210
Program-related data change/run command rejection error in
positioner mode
Change of program-related data or running of programs is prohibited in the positioner
mode.
277
Rejection error during program run
An attempt was made to reset all errors or reset one-revolution/rotation data when the
encoder is not permitted to reset all errors or reset one-revolution/rotation data while a
program is running.