121
Part 2 Programs
1.7 I/O, Flag Operation
BT
(Output port, flag operation)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
BT
Output,
flag
(Output,
flag)
CP
[Function]
Reverse the ON/OFF status of the output ports or flags from the one specified in operand 1
through the other specified in operand 2.
BT
ON
Switch the status to ON.
OF
Switch the status to OFF.
NT
Reverse
the
status.
[Example 1]
BTON
300
Turn ON output port 300.
[Example 2]
BTOF
300
307
Turn OFF output ports 300 through 307.
[Example 3]
LET
1
600
Assign 600 to variable 1.
BTNT
*1
Reverse the content of variable 1 (flag 600).
[Example 4]
LET
1
600
Assign 600 to variable 1.
LET
2
607
Assign 607 to variable 2.
BTON
*1
*2
Turn ON the flags from the content of variable 1 (flag
600) through the content of variable 2 (flag 607).