79
Part 2 Programs
Part 2 Programs
Chapter 1 SEL Language Data
1. Values and Symbols Used in SEL Language
1.1 List of Values and Symbols Used
The various functions required in a program are represented by values and symbols.
Function
Global range
Local range
Remarks
Input port
000 ~ 024
Varies depending on
the function.
Output port
300 ~ 307
Varies depending on
the function.
Flag
600 ~ 899 (300)
900 ~ 999 (100)
Variable (integer)
200 ~ 299 (100)
1200 ~ 1299 (100)
1 ~ 99 (99)
1001 ~ 1099 (99)
99 is used for IN, INB,
OUT, OUTB, etc.
Variable (real)
300 ~ 399 (100)
1300 ~ 1399 (100)
100 ~ 199 (100)
1100 ~ 1199 (100)
199 is used for PPUT,
PGET, PARG, etc.
String
300 ~ 999 (700)
1 ~ 299 (299)
Tag number
1 ~ 256 (256)
Subroutine number
1 ~ 99 (99)
Zone number
1 ~ 4 (4)
Pallet number
1 ~ 10 (10)
Axis number
1 ~ 2 (2)
Varies depending on
the function.
Axis pattern
0 ~ 11
Controller with
increased memory size
1 ~ 20000 (20000)
Position number
Controller without
increased memory size
1 ~ 1500 (1500)
Controller with
increased memory size
1 ~ 128 (128)
Program number
Controller without
increased memory size
1 ~ 64 (64)
Controller with
increased memory size
1 ~ 9999 (9999)
Step number
Controller without
increased memory size
1 ~ 2000 (2000)
Task level
NORMAL/HIGH (2)
SIO channel number
1 (0)
Wait timer
1
1-shot pulse timer
16 (Number of timers
that can be operated
simultaneously)
Ladder timer
Local flag (100)
Virtual input port (SEL system
SEL user program)
7000 ~ 7299 (300)
Virtual output port (SEL user
program
SEL system)
7300 ~ 7599 (300)
Number of symbol definitions
500
Controller with
increased memory size
5000 (including literal)
Number of times symbol can be
used in commands
Controller without
increased memory size
2500 (including literal)
Used in common from any program.
Referenced separately
in each program.
Cleared when the
program is started.
Caution
Variables 99 and 199 are special variables this system uses in operations.
Avoid using these two variables for general purposes.
The values in the table represent ranges that can be processed by
software. Items that require physical devices, such as I/O ports and
functions relating to axis number and SIO, will be determined by possible
combinations and models of commercial boards, etc., available for each
device application.
Summary of Contents for ssel
Page 1: ...Operation Manual Eighth Edition SSEL Controller ...
Page 26: ......
Page 50: ...25 Part 1 Installation 3 Specification with system memory backup battery optional ...
Page 385: ...359 ...
Page 495: ......
Page 496: ......