background image

Model Plate (Large)
 

Refer to “External Dimensions” 
for the attached position. 

Model Plate (Large)

Refer to “External Dimensions” 
for the attached position. 

Serial Number

 

-SC,

 

-PS2 

200V Power Supply Unit, 200V Driver Unit,   

Fan Unit, Terminal Unit for 200V 

 

First Step Guide    First Edition 

 

Thank you for purchasing our product. 

Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the 

product in addition to this First Step Guide to ensure correct use. 

This Instruction Manual is original.

 

 
 
 

 
 

  Using or copying all or part of this Instruction Manual without permission is prohibited. 

  The company names, names of products and trademarks of each company shown in the sentences 

are registered trademarks. 

R-unit constructs a systemwide combining the Gateway Unit (RCON/RSEL), 24V and 200V Driver Units, 
Extension Unit, Simple Absolute Unit, Fan Unit and Terminal Unit. 
In this guide, describes about the 200V Power Supply Unit, 200V Driver Unit, Fan Unit and Terminal Unit for 
200V. 
For instruction of other units, refer to the first step guide and instruction manual (DVD) of each unit. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

This product is comprised of the following parts if it is of standard configuration. 
If you find any fault in the contained model or any missing parts, contact us or our distributor. 

1.  Parts 

(1) 200V Power Supply Unit 

No. 

Part Name 

Model 

Number 

Remarks 

1  200V Power Supply 

Unit 

Refer to “How to read the model 

plate”, “How to read the model code” 

 

Accessories 

2  Terminal Unit for 200V  RCON-GW-TRS 

Not enclosed in TRN Type

3  Fan Unit 

RCON-FU 

 

4  Power Connector 

SPC5/4-STF-7.62 

(Manufactured by PHOENIX CONTACT) 

 

 

 

 

5  First Step Guide 

ME0397 

This Manual 

6  Safety Guide 

M0194 

 

 

(2) 200V Driver Unit 

No. 

Part Name 

Model 

Number 

Remarks 

1  200V Driver Unit 

Refer to “How to read the model 

plate”, “How to read the model code” 

 

Accessories 

2  Fan Unit for 200V Driver  RCON-FUH 

 

3  Dummy Plug 

DP-6 

 

 

 

 

4  First Step Guide 

ME0397 

This Manual 

5  Safety Guide 

M0194 

 

2. Teaching Tool (Please purchase separately) 

A teaching tool such as PC software is necessary when performing the setup for position setting, parameter 
setting, etc. that can only be done on the teaching tool. Please prepare either of the following teaching tools. 

No. 

Part Name

Model

1  PC Software   

SEL Controller: IA-101X/N

Position Controller: IA-OS 

RCM-101-MW/USB

2  Touch Panel Teaching Pendant TB-02 (Standard/ Dead Man’s Switch Mounted)

TB-02/TB-02D

3  Touch Panel Teaching Pendant TB-03

TB-03

3. Instruction manuals related to this product, which are contained in the instruction manual (DVD). 

No. 

Name

Manual No.

1  RCON System Instruction Manual

ME0384

2  RSEL System Instruction Manual

ME0392

3  PC Software RCM-101-MW/RCM-101-USB Instruction Manual

ME0155

4  PC Software IA-101-MW/USB Instruction Manual

ME0154

5  Touch Panel Teaching Pendant TB-02 Applicable for Position Controller Instruction Manual

ME0355

6  Touch Panel Teaching Pendant TB-02 Applicable for Program Controller Instruction Manual

ME0356

7  Touch Panel Teaching Pendant TB-03 Wired Link Applicable for Position Controller

Instruction Manual

ME0376 

8  Touch Panel Teaching Pendant TB-03 Wired Link Applicable for Program Controller

Instruction Manual

ME0377 

4. How to read the model plate (This design is what is after UL/CE acquired.) 

(1) 200V Power Supply Unit 

 
 
 
 
 
 
 
 
 
 

(2) 200V Driver Unit

 

 

 
 
 
 
 
 
 
 
 
 

(3) Fan Unit 

 
 
 
 
 
 
 

Mark 

Explanation of Mark 

 

Use IAI specified cables only. 
Where  residual-current-operated  protective  device  (RCD)  is  used  for 
protection in case of direct or indirect contact, only RCD of Type B is 
allowed on the supply side of this Electrotonic Equipment (EE).

 

Do  not  touch  terminals  within  10  minutes  after  disconnect  the  power. 
Risk of electric shock. 

 

Do not touch product when power is ON. Risk of burn. 

 

 

5. How to read the model code 

(1) 200V Power Supply Unit 

 
 
 
 
 
 
 
 
 
 

(2) 200V Driver Unit 

 
 
 
 
 
 

Type : SC 

60-700W

 

Motor 

 

1 axis

 

60 
100 
100 
150 
200 
200 
300 
400 
600 
750 

60W Servo-motor 
100W Servo-motor 
100W Servo-motor (for LSA) 
150W Servo-motor 
200W Servo-motor 
200W Servo-motor (for LSA, DD)
300W Servo-motor (for LSA) 
400W Servo-motor 
600W Servo-motor 
750W Servo-motor 

 

(3) Fan Unit 

 
 
 
 
 
 

1. Specifications of Power Supply 

Item 

Specification 

Power Input Voltage Range 

200 to 230V AC ±10%

Power Supply Frequency Range 

50/60Hz 

Current Amperage 

Refer to “Current Amperage”

In-Rush Current 

25A/axis (with in-rush current limit circuit)

Instantaneous Power Outage Endurance  20ms (with power supply frequency at 50Hz) 

16.3ms (with power supply frequency at 60Hz)

Protection Function against Electric Shock  Class 

 

Leak Current 

3.0mA or less 

2. Specifications of Control Part 

Item 

Specification 

Number of Controlled Axes 

RCON System 1 to 16 axes, RSEL System 1 to 8 axes 

Corresponding Motor Capacity 

60W to 750W 

Corresponding Encoder 

Incremental Serial, Battery-less Absolute, ABZ (UVW) Parallel, Spurious Absolute 
and Index Absolute 

Field Network Interface 

CC-Link, CC-Link IE Field, DeviceNet, EtherCAT, EtherNet/IP, PROFIBUS-DP, 

PROFINET IO 

Pulse Train Type 

Unavailable to Control 

Brake Output Voltage 

45V DC ±10% (Overexcitation 90V) 

Connectable Brake Power 

Max 7W 

Calendar Feature 

Maintained Duration: Approx. 10 days, Charge Time: Approx. 100 hours 

Applied Safety Category 

B (Safety category applicable type is capable to achieve 4 with external circuit) 

Driver Source Cutoff System 

Drive source cutoff with semiconductor (Power MOSFET) 

Stop Input 

Break Contact Input 

Stop Action 

Turning servo OFF + Drive source cutoff 

Enable Input 

None 

T. P. Enable Input 

Available 

Enable Action 

Turning servo OFF 

Protective functions 

Overcurrent, temperature error, encoder line breakage and overload 

Preventive / Predictive Maintenance Feature  Electrolytic capacitor capacity dropdown and Fan revolution dropdown 
Driver Unit LED Display 

Refer to “Troubleshooting (LED Display)” 

Brake Compulsory Release Feature 

Brake release switch equipped on 200V Driver Unit 

Jog 

Jog switch equipped on 200V Driver Unit 

Cable Length 

Motor Cable: 20m or less, Encoder Cable: 20m or less 

Oversea Certifications 

Planned to acquire CE and UL 

3. Environmental Specifications 

Item 

Specification 

Envi

ronm

en

Environment of Use 

Pollution Degree 2 

Surrounding Air Temperature 

0 to 55

Surrounding Humidity 

85% RH or less (non-condensing) 

Peripheral Ambience of Use 

Refer to “Installation Environment” 

Surrounding Storage Temperature 

-20 to 70

Vibration Durability 

Frequency 10 to 57Hz/Swing width: 0.075mm

Frequency 57 to 150Hz/Acceleration: 9.8m/s

2

 

XYZ Each direction    Sweep time: 10min.    Number of sweep: 10times

Protection Class 

IP20 

Altitude 

1000m 

Cooling Method 

Forced air cooling with fan unit 

Dielectric Withstanding Voltage 

1500V for 1 min between power supply terminal and PE 

Overvoltage category 

 

Product Check 

Basic Specifications 

Warning:  Operation of this equipment requires detailed installation and operation instructions 

which are provided on the DVD Manual included in the box this device was 

packaged in. It should be retained with this device at all times. 

A copy of the DVD Manual can be requested by contacting your nearest IAI Sales 

Office listed at the back cover of the Instruction Manual or on the First Step Guide.

1B

Fan Unit 

200V Power 
Supply Unit 

Fan Unit for 200V Driver 

200V Driver Unit 

Terminal Unit for 
200V 

Model

Serial Number

Model

Model Plate (small)

It is attached on the 
bottom of the panel 
front face. 

Model

Serial Number

Model Plate (small)

It is attached on the 
bottom of the panel 
front face. 

Serial 

Model

(Partially)

Serial Number

Model

R C O N

 

-

 

S C

 

-

 

1  

<Number of Axes>
1 : 1 axis

<

 

Series >

 

<Type> 
SC : 200V AC Servo-motor 

<Type>

 

FU  : Fan Unit 
FUH : Fan Unit for 200V

R C O N

 

-

 

F U H  

<

 

Series >

 

R C O N

 

-

 

P S 2

 

-

 

3

 

- T R N

 

<

 

Series >

<Power-supply Voltage > 
3 : Single-phase/Three-phase 200V

<Type> 
PS2 : 200V   

Power Supply Unit

<Option>

 

TRN : With No Terminal Unit

Summary of Contents for RCON-SC

Page 1: ...00V Power Supply Unit 2 200V Driver Unit Type SC 60 700W Motor 1 axis 60 100 100 150 200 200 300 400 600 750 60W Servo motor 100W Servo motor 100W Servo motor for LSA 150W Servo motor 200W Servo motor 200W Servo motor for LSA DD 300W Servo motor for LSA 400W Servo motor 600W Servo motor 750W Servo motor 3 Fan Unit 1 Specifications of Power Supply Item Specification Power Input Voltage Range 200 to...

Page 2: ... Driver unit with brake 0 5A 16 8 0A OK Example 3 24V Actuator 8 axes All axes equipped with brake 2 axes unit All axes simple absolute type 200V Actuator 8 axes All axes equipped with brake 24V Driver unit with brake 0 6A 4 Simple absolute 0 2A 8 200V Driver unit with brake 0 5A 8 8 0A OK Example 4 200V Actuator 16 axes All axes equipped with brake PIO SIO SCON Extension Unit one unit PIO Unit 7 ...

Page 3: ...cation exposed to direct sunlight Location where the product may come in contact with water oil or chemical droplets Environment that blocks the air vent Refer to Installation and Noise Elimination When using the product in any of the locations specified below provide a sufficient shield Location subject to electrostatic noise Location where high electrical or magnetic field is present Location wi...

Page 4: ...tor The motor power should be cut off by STOP Signal The drive source cutoff circuit by semiconductor possesses features to detect the overcurrent and to limit the in rush current Note 1 RCON GW If nothing is connected to the SIO connector S1 and S2 will be short circuited in the controller RCON GWG If nothing is connected to the SIO connector S1 and S2 will not be short circuited in the controlle...

Reviews: