Fieldbus Communication
12
RCP6S
■
Name for Each Parts and Their Functions
■
1. Controller Unit in RCP6S (Built-in Controller Type)
1) Power / Communication line Connector [Refer to Chapter 2]
It is a connector that the gateway unit, hub unit or PLC unit etc. is to be connected.
2) Status Indicator LED
Following show the controller operation status:
{
: Illuminating × : OFF
☆
: Flashing
LED
Color
Operation Status
×
-
Operation status
Servo OFF
RD
Alarm (Operation cancellation level or more)
In the emergency stop
RD
During crash detection
GR
Servo ON
GR
Motor driving power supply OFF
(Note 1)
OR
In initializing process when the power is turned on
Note 1 Signal during automatic servo-off : [Refer to Chapter 6]
3) Communication (SIO) Connector [Refer to 2.3.5 SIO Connector Connection]
The SIO connector is used to connect the controller with a teaching tool through a proper
communication cable.
* There is no SIO connector equipped on the dust and drip proof type (RCP6SW).
A teaching tool should be connected to the gateway unit for operation.
1) Power / Communication
line Connector
3) Communication (SIO)
Connector
2) Status Indicator LED
ME0349-4B
Summary of Contents for RCM-P6AC
Page 2: ......
Page 9: ...Fieldbus Communication RCP6S ME0349 4B ...
Page 32: ...Fieldbus Communication 20 RCP6S ME0349 4B ...
Page 86: ...2 Wiring Fieldbus Communication 74 RCP6S ME0349 4B ...
Page 178: ...3 Operation Fieldbus Communication 166 RCP6S ME0349 4B ...
Page 184: ...4 Vibration Suppress Control Function Fieldbus Communication 172 RCP6S ME0349 4B ...
Page 192: ...6 Power saving Function Fieldbus Communication 180 RCP6S ME0349 4B ...
Page 196: ...7 Absolute Reset Fieldbus Communication 184 RCP6S ME0349 4B ...
Page 284: ......