Chapter 3 Operation
POWER CON
PCON-CB/LC
85
[4] Home Return (HOME, HEND, PEND, MOVE)
Input Output
PIO signal
HOME HEND PEND MOVE
Patterns 0 and 1
{
{
{
{
Patterns 2 to 4
{
{
{
×
Pattern 5
×
(Note1)
{
×
×
{
: Available,
×
: Unavailable
Note 1: For pattern 5, the home return by the HOME signal is not allowed. Refer to 3.2.6 [1]
Home return (ST0, HEND) for how to perform a home-return operation.
The HOME signal is intended for automatic home return. The HOME signal is caught at the
rising edge (ON edge) to start the home return. At completion of the home return, home return
completion signal HEND is turned ON. The home-return complete signal HEND is kept on
unless the memory of origin point is lost for a reason such as alarm. During the home return
operation, positioning completion signal PEND and moving signal MOVE are set to OFF and
ON, respectively.
Home Return Completion Signal
HEND
(Controller→PLC)
Positioning Completion Signal
PEND
(Controller→PLC)
Moving Signal
MOVE
(Controller→PLC)
Home Return Signal
HOME
(PLC→Controller)
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......