Chapter 2 Wiring
POWER CON
PCON-CB/LC
68
2.3.4 Connection of Pulse Train Signal
Pulse train is input to PIO connector.
Insert the wires to the indicated pin numbers.
[Refer to 2.2.3 [4] Circuits for Pulse Train Control]
If the output pulse of the host controller is open collector type, use the following pulse
converter.
●
Pulse converter : AK-04
(to be purchased separately)
It converts the command pulse of the open collector type to the differential type.
Host Controller
(PLC etc.)
IAI controller
e-CON Connector (Accessories)
Caution
1) Pay attention not to insert wrongly because it is the same e-CON connector as input and
output. Putting the power on with the insertion being wrong will burn AK-04.
2) Use the pulse converter in the ambient temperature range between 0
°
C and 40
°
C.
3) The temperature increase of about 30
°
C occurs during operation. Accordingly, neither
install several pulse converters in close contact nor install them within a duct. Do not
install the pulse converter near other heating devices.
4) If more than one pulse converters are installed, set a pulse converter apart from another by
10mm or more.
5) Make the wiring between the host controller (PLC, etc.) and AK-04 as short as possible.
Long wires make it easy to pick up noise. Also make the wiring between AK-04 to this
controller as short as possible.
Place AK-04 close to the host controller.
A recommended installation sample is shown in the figure below.
• Make the cable length between the host
controller and pulse converter as short as
possible.
Wiring length :
50mm or shorter recommended
Host Controller
• Keep pulse converters separated for 10mm or
more from each other.
10mm or more
10mm or more
If this installation cannot be
avoided, shorten the length of
the wiring with the host
controller as much as possible.
e-CON Connector (Accessories)
Connector Color
Applicable Cable Diameter
Model
(manufactured by Sumitomo 3M)
Body Black, Cover Yellow AWG24 to 26
37104-3122-000FL
Body Gray, Cover Red
AWG26 to 28
37104-4101-G00FL
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......