![IAI PCON-CB series Instruction Manual Download Page 133](http://html1.mh-extra.com/html/iai/pcon-cb-series/pcon-cb-series_instruction-manual_603995133.webp)
Chapter 3 Operation
POWER CON
PCON-CB/LC
119
[3] Pressing Operation
Sample use
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Transported
load
Stop
mode
0
1 0.00 250.00 0.20 0.20
0
0
0.10
0.00
0.00
0 0
0
0
2 100.00 250.00 0.20 0.20
50
0
50.00
0.00
0.00
0 0
0
0
(Position No.2 sets pressing operation.)
Control method
1) The method of controlling the pressing operation is the same as that described in [1]
Positioning except the setting of the position table. Any setting of “Pressing” in the position
table allows the pressing operation to be done. “Positioning width” is assumed as pressing
operation distance.
2) The actuator moves at the setting speed and rating torque to the position of the coordinate
set in “Position” in the similar way as normal positioning. The operation is executed with the
value set in “Positioning Band” for the amount of movement in the pressing operation, and
the torque (current limit) set in % in “Pressing” for the pressing operation as the upper limit.
3) The control method is the same as that in [1] Positioning. However, the processing of
positioning complete signal PEND is different from that in [1] Positioning.
PEND is output when the shaft is stopped by pressing (pressing complete). If the work is
not subject to pressing (miss-pressing), the actuator moves by the value set in “Positioning
width” to stop but PEND is not turned ON. The current position No. PE* is turned ON at the
completion of pressing and even in miss-pressing.
Positioning
Completion
1)
2)
3)
4)
1)
3) 4)
2)
Positioning width 50
Velocity
Press-fitting process
Caulking process
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......