Chapter 3 Operation
POWER CON
PCON-CB/LC
115
3.2.5 Direct Position Specification (Solenoid Valve Mode 1) = Operation of
PIO Pattern 4
The start signal is provided for every position number. Only turning ON the relevant input signal
according to the table shown below allows the operation based on the data in the target
position number to be performed. The operation mode is called the solenoid valve mode
because solenoid valves can directly drive air cylinders.
At the completion of positioning, every completed position number is output as well as the
positioning complete signal.
Positioning, pressing, and pitch feed are possible. Their control methods are the same as those
of other patterns.
[1] Positioning [Basic] (ST0 to ST6, PE0 to PE6, PEND)
Position No.
Input
Output
0 ST0 PE0 PEND
1 ST1 PE1 PEND
2 ST2 PE2 PEND
3 ST3 PE3 PEND
4 ST4 PE4 PEND
5 ST5 PE5 PEND
6 ST6 PE6 PEND
(Note)
•
Speed change is not allowed during movement.
•
For incremental type, if start signal ST* is issued without home return, the home
return operation is automatically done before the operation based on the data of
the specified position number. When this specification is not desired, interlock by
home return complete signal HEND is required. Operation to the specified position
number would not take place under the condition that the home position data is
lost in the simple absolute type, but only the home-return operation will be
conducted.
Sample use
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Transported
load
Stop
mode
0 0.00 100.00 0.20 0.20
0
0
0.10
0.00
0.00
0 0
0
0
1 70.00 100.00 0.20 0.20
0
0
0.10
0.00
0.00
0 0
0
0
2 150.00 200.00 0.20 0.20
0
0
0.10
0.00
0.00
0 0
0
0
Velocity
1)
2)
3)
4)
5)
6)
1)
2) 3)
4)
5) 6)
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......