LQ-401CL
36
Note: EEN uses channel with the largest exposure value
Fig.40 Shutter–Select mode/Sub-sampling and Window/ Internal
6.3.5 Shutter-Select mode with external trigger
In this mode, the exposure and readout is activated by the external trigger pulse.
In this mode, the exposure time of R, G, B and NIR channel can be adjusted independently.
To use this mode:
Set function
Trigger
TR=1
Trigger origin, external
TG=1
Individual R, G, B and NIR exposure
EI=0(individual)
EI=1(tracking with G)
Programmable exposure
PER/PEG/PEB/PEIR=840 to 1194752
(9.52 µs to 14.20 ms in 11.9 ns increments)
Important note:
If using individual exposure, the EEN signal represents the channel with the longest exposure time
The minimum trigger interval
Scan mode
Trigger input via
Minimum interval (
µ
s)
Full/Binning
Camera link
54.8
Hirose 12-pin
59.3
Sub-sampling/windowing
Camera link
30.4
Hirose 12-pin
34.9
EEN
* Note
Exposure R
Exposure G
Exposure B
Exposure NIR
610clk
LVAL
16clk
2048clk
16clk
DVAL
Data
AP0
AP2047