LQ-401CL
31
Fig.34 No-Shutter /Sub-sampling and Window/ Internal
6.3.3 No-Shutter mode with external trigger
In this mode, the accumulation and readout is activated by an external trigger pulse. The
exposure period depends on the trigger interval and if the trigger interval becomes longer, the
sensitivity is increased.
To use this mode:
Set function
Trigger mode, No-Shutter
TR=0
Trigger origin, external
TG=1
Trigger input
TI=0 or 1
Important note:
In this mode, the shutter cannot be used.
Only gain based one-push white balance functions (WB) are available with this mode.
The jitter generated in the trigger input causes a variation of exposure time.
Minimum trigger interval
Scan mode
Trigger input via
Minimum interval (
µ
s)
Full/Binning
Camera link
54.8
12-pin
59.3
Sub-sampling/windowing
Camera link
30.4
12-pin
34.9
Minimum trigger pulse width
Trigger input via
Minimum trigger pulse width
Camera link
500 ns
12-pin
5 µs
450clk
EEN
610clk
LVAL
16clk
2048clk
16clk
DVAL
Data
AP0
AP2047