44
8
Trouble shooting
Problem
Cause
Solution
No power
Main power switch of
Turn on power switch.
Empty battery
Charge battery.
Fuse has blown
Replace fuse.
No steam
SELF-LOCK button is turned off
Turn on the SELF-LOCK button.
No gas cartridge(s)
Insert gas cartridge(s).
Empty gas cartridge(s)
Replace gas cartridge(s).
Gas valve is closed
Turn on gas valve.
Ventilator is not running
Contact your service
department.
Pump is not running
Pump needs to be replaced by
a skilled mechanic.
Steam is blocked
Turn off the machine, check
and clean the brush and steam
nozzle.
Fluid level LED light
flashes
Gum remover solution is low
Turn-off and cool-down the
machine. Fill the tank with
gum remover solution.
Fluid leak from tank
Yellow stopper is not put back
correctly
Check and place the yellow
stopper correctly.
Machine was stored or transported
lying down without draining the tank
first
Place the machine upright.
Battery not charging
Battery is end of life
Replace battery.