Off:
The privacy zone will not be displayed.
•
Default:
Off
[Delete] button
Click the [Delete] button corresponding to the zone to be deleted.
[Close] button
Click this button to close the “Privacy zone” setup menu.
IMPORTANT
•
After configuring the privacy zone, the privacy zone may move out of alignment when “Image
rotation” of the [Basic] tab is changed. Make sure to check the privacy zone after changing the setting.
•
After configuring the privacy zone, the privacy zone may move out of alignment when the “Extra optical
zoom” setting is changed. Make sure to check the privacy zone after changing the setting.
3.6.4.5 Configure the VIQS setting
Click the [Setup>>] button of “VIQS” on the [Image quality] tab of the “Image/Audio” page. (
®
the settings relating to image adjust, privacy zone, VIQS, and lens distortion compensation [Image quality]”)
VIQS is an abbreviation of Variable Image Quality on Specified area and is a feature that enables you to change
the images of a specified area.
It is possible to enhance the image quality of the specified range within a shooting area (image).
It is also possible to moderate the image data size by lowering the image quality of other areas.
The VIQS setting is available only for H.265 (or H.264) images.
Up to 8 VIQS areas can be set.
To check the image after configuring VIQS, when H.265 (or H.264) images are selected under “Stream”, you
can check the image by pressing the [Confirm] button. You can also check by displaying an H.265 (or H.264)
image on the “Live” page.
The VIQS function is not available in the following cases:
•
When “On(High)” or “On(Low)” is set for “Smart VIQS” of “Stream(1)”
•
When “On” is selected for “Smart P-picture control”
[Area]
When selecting a VIQS area in the screen, it will be numbered as area 1. (Subsequent areas will be numbered
in the order of selection.)
[Status]
Select “On” or “Off” to determine whether or not to use the VIQS area.
•
On:
The VIQS area will be set.
•
Off:
Does not set the VIQS area.
•
Default:
Off
[Delete] button
Deletes the VIQS area. Click the button to delete the VIQS area.
[Level]
Configure the difference level in the image quality between specified areas and non-specified areas. The
greater the difference level, the more the image quality of the non-specified area is reduced. This makes it
possible to moderate the image data size.
0 Min./ 1/ 2/ 3/ 4/ 5 Normal/ 6/ 7/ 8/ 9 Max.
•
Default:
5 Normal
Operating Instructions
99
3 Detailed Settings