i-PRO WV-QDC500 Operating Instructions Download Page 1

Operating Instructions

Included Installation Instructions

Dome Cover

Model No.   

WV-QDC500

Precaution

 

„

Do not use this product except with suitable cameras.

Failure to observe this may cause a drop resulting in injury or accidents.

 

„

Refer installation work or dome cover replacement to the dealer.

Installation work requires technique and experiences.
Failure to observe this may cause fire, electric shock, injury, or damage to the product.
Be sure to consult the dealer.

 

„

The screws and bolts must be tightened to the specified torque.

Failure to observe this may cause a drop resulting in injury or accidents.

When using this product, also read the “Precautions” described in the operating 
instructions for the camera to be attached.

•  Before attempting to connect or install this product, please read these instructions carefully and 

save this manual for future use.

•  The external appearance and other parts shown in this manual may differ from the actual product 

within the scope that will not interfere with normal use due to improvement of the product.

•  Read also the installation guide of the camera to be used.

i-PRO Co., Ltd. assumes no responsibility for injuries or property damage resulting 
from failures arising out of improper installation or operation inconsistent with this 
documentation.

"<Control No.: C****>" used in these documents should be used to search for information 
on our technical information website (https://i-pro.com/global/en/surveillance/training-
support/support/technical-information) and will guide you to the right information. 

https://www.i-pro.com/

© i-PRO Co., Ltd. 2023

Cs0620-2023

Printed in China

Preface

This product is the clear type dome cover. <WV-QDC500C>
This product is the smoke type dome cover (approx. 45 % of transmittance). <WV-QDC500S>

The latest information about the supported cameras
<Control No.: C0501>

Specifications

Ambient operating temperature: –50 °C to +60 °C {–58 °F to +140 °F}
Dimensions:

ø71 mm × 37.5 mm (H) {ø2-25/32 inches} × {1-15/32 inches} (H)
Diameter of the dome: 30.5 mm {1-3/16 inches}

Mass:

Approx. 20 

g

 {0.04 lbs}

Finish:

PC resin

Clear <WV-QDC500C>
Smoke <WV-QDC500S>

Installation 

Read the following descriptions together with the Installation Guide of the camera.

Note:

•  When a smoke type dome cover is used, the IR LED irradiation distance and the illuminance 

level are lower than for a standard clear type dome cover.  
Check the settings after attaching the enclosure. 

Step 1

Loosen enclosure fixing screws (3 places), 

and remove the enclosure from the camera.

<Outdoor camera>

Loosen the screws using the bit (camera accessory).

<Indoor camera>

Loosen the screws using a Phillips screwdriver.

* The right illustrations are examples of outdoor use 

camera.

Step 2

Remove the dome cover.

① 

Remove the fixing screws (3 pcs.) that secure the dome cover anchor bracket to the enclosure.

② 

Remove the dome cover anchor bracket and the dome cover.

Note:

•  These fixing screws (3 pcs.) and the dome cover anchor bracket will be used again in step3. 
• 

Be careful to the following when replacing the dome cover: (outdoor camera only)

-   The waterproof rubber may come off simultaneously. Attach the waterproof rubber to the 

original position before attaching this product.

-   It is recommended to check whether the waterproof rubber is deteriorated. When it has 

deteriorated, the waterproof performance will decrease, so consider repairing it.

<Outdoor camera>

<Indoor camera>

Dome cover 

anchor bracket

Dome cover

Fixing screw 

(3 pcs.)

Enclosure

Dust guard 

sponge

Bit (camera accessory)

Enclosure

Enclosure fixing

 

screw 

(3 places)

Step 3

Replace the dome cover.

① 

Remove the protection film from the outside of the dome cover (this product). Keep the removed 
protection film for following step. (Take care not to damage the outside or inside of this product.)

 

w

Attach this product to the enclosure. 

 

e

Using the fixing screws (3 pcs.) that were removed in step2, secure the dome cover anchor 
bracket to the enclosure.

 

r

Attach the protection film removed in 

 to the outside surface of this product.

Recommended tightening torque: 

0.40 N·m {0.30 lbf·ft}

<Outdoor camera>

<Indoor camera>

Dome cover 

anchor bracket

Dome cover

Fixing screw 

(3 pcs.)

Enclosure

Dust guard 

sponge

Note:

•  Do not remove the dust guard sponge adhered to the dome cover anchor bracket. 

(Indoor camera only)

Step 4

Attach the enclosure to the camera.

Tighten the enclosure fixing screws (3 places) using the bit (camera accessory) or Phillips screwdriver.

 Refer to the Installation Guide of the camera for more information about installing the camera.

Recommended tightening 

torque: 0.70 N·m {0.52 lbf·ft}

Caution:

•  Before attempting to connect or operate this product, please read these instructions carefully.

Standard accessories 

Operating instructions (this document) .......................................................................................1 pc.