2.

First pass the coaxial cable through the BNC connector cover (accessory), then
connect the coaxial cable to the BNC connector of the camera side unit.

To receiver side unit

BNC connector

Coaxial cable

BNC connector cover

(Included parts of camera side unit)

IMPORTANT

When connecting the coaxial cable to the unit, make sure that no other
devices are connected to the coaxial cable. Connecting the coaxial cable to
the unit when there are other devices connected (such as an analog CCTV
camera), may cause damage to the connected device.

When using existing coaxial cables, disconnect other devices that are
connected to the coaxial cable before connecting to the unit.

Measure the insulation resistance of the coaxial cable (new or existing) before
making connections.
Insulation resistance value: 1 M

W

 or more for DC 500 V

Confirm the length of the coaxial cable when using the PoE function (see
page 31, page 33).

36

Operating Instructions

4 Connecting the Unit

Summary of Contents for WJ-PR204

Page 1: ...o WJ PR204 WJ PR204E RECEIVER 4 channel WJ PR201 WJ PR201E RECEIVER 1 channel WJ PC200 WJ PC200E CAMERA WJ PC200 WJ PR204 Before attempting to connect or operate this product please read these instruc...

Page 2: ...onforme ai seguenti standard o altri documenti normativi conformi alle disposizioni delle direttive 2006 95 CE e 2004 108 CE Wij verklaren als enige aansprakelijke dat het product waarop deze verklari...

Page 3: ...must not be used until a replacement cover is obtained A replacement fuse cover can be purchased from our dealer IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE F...

Page 4: ...pparatus 10 Only use attachments accessories specified by the manufacturer 11 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart...

Page 5: ...1 When using a 1 channel Receiver Side Unit 31 4 1 2 When using a 4 channel Receiver Side Unit 33 4 2 Connections 35 5 Maintenance Screen of coaxial LAN converter 42 5 1 Accessing the Maintenance Scre...

Page 6: ...h these notation are available when using the model WJ PR204 WJ PR204E Receiver side unit 1 channel PR201 The functions with these notation are available when using the model WJ PR201 WJ PR201E Camera...

Page 7: ...nverter is capable of transmission speeds of 35 Mbps or over for TCP 2 and 45 Mbps or over for UDP connections 2 When used with RG 6 U coaxial cable and for distances under 2 0 km 6 560 feet PR201 500...

Page 8: ...rmal use due to improvement of the product Trademarks Microsoft Windows Windows Vista Windows Media Internet Explorer and ActiveX are either registered trademarks or trademarks of Microsoft Corporatio...

Page 9: ...BE LIABLE TO ANY PARTY OR ANY PERSON EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT FOR THE CASES INCLUDING BUT NOT LIMITED TO BELOW 1 ANY LOSS OR DAMAGE INCLUDING WITHOUT LIMITATION...

Page 10: ...uter viruses or other malicious entities using a regularly updated anti virus program anti spyware program etc After the unit is accessed by the administrator make sure to close the browser Do not ins...

Page 11: ...nnector Cover cap 3 pcs 2 PR204 BNC Connector Cover 1 ch 1 pc PR201 Screw M2 6 10 mm 3 8 inches 2 pcs of them 1 for spare WJ PC200 WJ PC200E Operating Instructions this document 1 pc BNC Connector Cov...

Page 12: ...weight Selecting an inappropriate installation surface may cause this product to fall down or topple over resulting in injury or accidents Installation work shall be started after sufficient reinforc...

Page 13: ...product Failure to observe this may cause fire or electric shock Consult the dealer for the repair or inspections Do not insert any foreign objects Fire or electrical shock may be caused if water or...

Page 14: ...cables insert objects into the conductor or connect coaxial cables with incomplete relays If water or other objects enter the conductor or coaxial cables with incomplete relays are connected it may re...

Page 15: ...he unit 1 6 General Precautions Follow the instructions written in Important safety instructions see page 4 and 1 5 For Your Safety see page 12 together with the instructions written below 1 Follow th...

Page 16: ...l or any other types of solvents or detergents Otherwise it may cause discoloration When using a chemical cloth for cleaning read the caution provided with the chemical cloth product 8 Cleaning stains...

Page 17: ...have been exposed to water or moisture 2 Do not install or use the unit near medical equipment High frequency signals emitted from the unit may affect the operation of medical equipment and cause mal...

Page 18: ...h thick area of the ceiling or wall such as a crossbeam otherwise the camera side unit may fall If there is no crossbeam place a board on the other side of the ceiling or wall to make sure the camera...

Page 19: ...efore making connections Insulation resistance value 1 MW or more for DC 500 V Confirm the length of the coaxial cable see page 31 page 33 We recommend RG 6 U coaxial cable The performance of the coax...

Page 20: ...as make sure to turn off the power from the receiver side before starting work and the turn on the power once the work has been completed When the receiver side is connected to a PoE hub as well as an...

Page 21: ...ide unit is connected to the camera side unit see page 25 Note The WJ PR204 is used as an example in some of the illustrations in this document Rear view WJ PR201 WJ PR201E A C B A BNC connector Conne...

Page 22: ...unit with a coaxial cable see page 38 B Network connector Connects the receiver side unit to a network device with an Ethernet cable see page 39 C DC IN Connects the receiver side unit to the power o...

Page 23: ...it with a coaxial cable see page 36 D PoE on off switch You can turn the PoE function on or off for the unit with this switch It is turned to ON by default IMPORTANT Turn the switch to ON when using t...

Page 24: ...Rear view PC200 A Used when attaching the camera side unit to a ceiling or wall with screws see page 26 24 Operating Instructions 2 Parts and functions...

Page 25: ...Green lit The camera side unit is connected to the receiver side unit through the coaxial cable When using the WJ PR204 the indicator lights even if only 1 camera is connected to the camera side unit...

Page 26: ...ause transmission interference When mounting several camera side units in the same area mount them side by side each other The pull out strength of the installation area must be at least 294 N 66 1 lb...

Page 27: ...ding on where the rack mount connecting fitting was purchased For U S and Canada BY HCA10A For Europe and other countries BY HCA10CE Mounting 2 to 4 receiver side units to a rack 1 Connect the receive...

Page 28: ...inches Keep the remaining parts Connecting 4 receiver side units Recommended torque 0 7 0 3 N m 0 52 0 22 lbf ft Flat head M3 6 mm 1 4 inches Rack mount connecting fitting accessory 16 Underside cont...

Page 29: ...itting accessory 2 Mounting bracket Rack mount connecting fitting accessory Mounting bracket Rack mount connecting fitting accessory Screw M3 6 mm 1 4 inches Rack mount connecting fitting accessory 2...

Page 30: ...k mounting screw locally procured 4 When mounting to a rack we recommend that you attach a cooling fan or other device to keep the units cool IMPORTANT Take measures to ensure that the temperature in...

Page 31: ...nnected Receiver side unit power source Camera power source Camera side unit Ethernet cable length A Receiver side unit Ethernet cable length B Compatible coaxial cable length C AC adaptor PoE Max 50...

Page 32: ...r information about recommended network cameras visit our web site https i pro com global en surveillance training_support support technical_information 2 Use a PoE camera that consumes no more than 6...

Page 33: ...length C AC adaptor PoE Max 50 m 164 feet Max 100 m 328 feet Max 200 m 656 feet PoE camera Max 300 m 984 feet Recommended cameras 1 PoE Max 100 m 328 feet Max 100 m 328 feet Max 300 m 984 feet PoE ca...

Page 34: ...not be connected Use Cat 5e or higher Ethernet cables Use 8 wire 4 pair Ethernet cables Use an Ethernet cable to connect the camera directly to the camera side unit Do not connect a hub between the ca...

Page 35: ...efore finally connecting the AC adaptor s plug to the power outlet When using a PoE power supply device connect the PoE power supply device to the network connector of the receiver side with an Ethern...

Page 36: ...able Connecting the coaxial cable to the unit when there are other devices connected such as an analog CCTV camera may cause damage to the connected device When using existing coaxial cables disconnec...

Page 37: ...the BNC connector cover caps accessory and pass the coaxial cables through the BNC connector cover When passing the coaxial cables through the BNC connector cover as shown in the figure below and conn...

Page 38: ...ector cover cap accessory BNC connector cover Accessory of receiver side unit Coaxial cable The illustrations below show an example to establish the 2 channel connection to a 4 channel unit model The...

Page 39: ...kgf cm Screw body diameter 2 6 10 mm 3 8 inches accessory of receiver side unit BNC connector cover accessory of receiver side unit 6 Connect a ethernet cable Cat 5e or higher to the receiver side un...

Page 40: ...eceiver side unit When you operate the receiver side unit the power outlet should be near the receiver side unit and easily accessible To prevent the AC cord from being disconnected if it is pulled do...

Page 41: ...r the IP address of the camera and press the Enter key The live image of the connected camera is displayed on the PC screen If the factory default IP address of the camera is 192 168 0 10 Address to e...

Page 42: ...tting PC see page 45 In order to access the coaxial LAN converter s maintenance screen you must temporarily change the IP address assigned to your computer Before you change the IP address of your com...

Page 43: ...C in the Windows 7 system In Microsoft Windows 7 this procedure must be performed by either the Administrator user or a user assigned with administrator level privileges Refer to the help file include...

Page 44: ...current IP address and other settings so that you can return the computer to those settings after you have connected and configured the unit 6 Click Close to exit the Local Area Connection Properties...

Page 45: ...coaxial cable and that the receiver side unit is turned on PC PC B A C C B A 2 Start the computer s web browser 3 Enter http 192 168 249 249 in the web browser s address bar 4 Enter the user name and...

Page 46: ...can display the maintenance screen and perform firmware updates etc The maintenance screen is displayed in English The display differs between the receiver side and the camera side units The upper pic...

Page 47: ...nverters to the computer to access their maintenance screens because the information ARP table of the previously connected coaxial LAN converter is retained the maintenance screen may not be able to b...

Page 48: ...boot version Firmware version Displays the coaxial LAN converter s firmware version Operation mode Displays the coaxial LAN converter type receiver side unit or camera side unit Camera side units are...

Page 49: ...scription MAC address of the Master only displayed for the camera side unit Displays the MAC address of the connected receiver side unit Operating Instructions 49 5 Maintenance Screen of coaxial LAN c...

Page 50: ...ter will automatically restart After restarting the updated firmware is used IMPORTANT When you update the coaxial LAN converter firmware be sure to download the latest version of the coaxial LAN conv...

Page 51: ...e used by the device that is to be connected to the camera side unit 1 Access the maintenance screen of the coaxial LAN converter 2 Click Option 3 Enter the desired IP address 4 Enter the subnet mask...

Page 52: ...dicator is not lit The coaxial cable is not connected Connect the coaxial cable see page 36 37 Confirm that the coaxial cable is not too long and is connected properly see page 31 33 35 Confirm that t...

Page 53: ...e unit is not connected Connect the camera side unit and receiver side unit with a coaxial cable Note When using the WJ PR204 the indicator lights even if only 1 camera is connected to the camera side...

Page 54: ...n cannot supply power to devices connected at distances Confirm that the connected ethernet cable is connected properly and is a PoE standard cable see page 31 33 and that there are no connection prob...

Page 55: ...f the unit gets extremely hot disconnect the power plug and contact an authorized service center Other than those above Refer to our support site below https i pro com global en surveillance training_...

Page 56: ...ut condensation Storage Environment Temperature 20 to 60 C 4 F to 140 F Humidity 10 to 95 without condensation Interfaces 10BASE T 100BASE TX 1 BNC connector 1 PR201 BNC connector 4 PR204 Dimensions W...

Page 57: ...NC connector cover is mounted Width approx 76 mm 3 inches Height approx 156 mm 6 5 32 inches Depth approx 36 mm 1 7 16 inches Mass Weight About 110 g 0 24 lb Finish Main unit PC ABS sail white BNC con...

Page 58: ...as For more information see page 33 For information about the specified cameras visit our website https i pro com global en surveillance training_support support technical_information 2 The maximum di...

Page 59: ...feet Camera powered by an external power supply PR201 1 This value is the total value of the transmission speed between the receiver side and camera side unit The transmission speed when using an RG 6...

Page 60: ...By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment For more information about collection and recycl...