background image

2

The lightning flash with arrowhead symbol, 
within an equilateral triangle, is intended to 
alert the user to the presence of uninsulat-
ed "dangerous voltage" within the prod-
uct's enclosure that may be of sufficient 
magnitude to constitute a risk of electric 
shock to persons.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

 DO NOT REMOVE COVER (OR BACK).

 NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

Before attempting to connect or operate this product, please 
read the label on the bottom.

The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the appliance.

Power disconnection. Unit with or without ON-OFF switches 
have power supplied to the unit whenever the power cord is 
inserted into the power source; however, the unit is opera-
tional only when the ON-OFF switch is in the ON position. 
Unplug the power cord to disconnect the main power for all 
units.

WARNING:

• This apparatus must be earthed.
• Apparatus shall be connected to a main socket outlet with a 

protective earthing connection.

• The mains plug or an appliance coupler shall remain readily 

operable.

• To prevent fire or electric shock hazard, do not expose this 

apparatus to rain or moisture.

• The apparatus should not be exposed to dripping or splash-

ing and that no objects filled with liquids, such as vases, 
should be placed on the apparatus.

• All work related to the installation of this product should be 

made by qualified service personnel or system installers.

• For PERMANENTLY CONNECTED APPARATUS provided nei-

ther with an all-pole MAINS SWITCH nor an all-all pole circuit 
breaker, the installation shall be carried out in accordance 
with all applicable installation rules.

• The connections should comply with local electrical code.

Safety Information

In 

English

: “The equipment must be connected to an earthed 

mains socket-outlet”.
In 

Danish

: “Apparatets stikprop skal tilsluttes en stikkontakt 

med jord, som giver forbindelse til stikproppens jord”.
In 

Finnish

: “Laite on liitettävä suojakoskettimilla varustettuun 

pistorasiaan”.
In 

Norwegian

: “Apparatet må tilkoples jordet stikkontakt”.

In 

Swedish

: “Apparaten skall anslutas till jordat uttag”.

For Denmark, Finland, Norway, Sweden

: Alternating current symbol

: Frame or chassis symbol

CAN ICES-3(A)/NMB-3(A)

For Canada

The model number and serial number of this product may 
be found on the surface of the unit.
You should note the model number and serial number of 
this unit in the space provided and retain this book as a 
permanent record of your purchase to aid identification in 
the event of theft.

  Model No. 

  Serial No.

For U.S.A.

NOTE: This equipment has been tested and found to com-

ply with the limits for a Class A digital device, pursuant to 

Part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference 

when the equipment is operated in a commercial environ-

ment. This equipment generates, uses, and can radiate 

radio frequency energy and, if not installed and used in 

accordance with the instruction manual, may cause harm-

ful interference to radio communications.

Operation of this equipment in a residential area is likely to 

cause harmful interference in which case the user will be 

required to correct the interference at his own expense.

FCC Caution: To assure continued compliance, (example - 

use only shielded interface cables when connecting to 

computer or peripheral devices). Any changes or modifi-

cations not expressly approved by the party responsible 

for compliance could void the user's authority to operate 

this equipment.

For U.S.A.

UL listed model No.:
WJ-NX300K

For U.S. and Canada:
WJ-NX300K
For Europe and other countries:
WJ-NX300K/G

Summary of Contents for WJ-NX300K

Page 1: ...please read these instructions carefully and save this manual for future use The model number is abbreviated in some descriptions in this manual Important Information Network Disk Recorder Model No W...

Page 2: ...accordance with all applicable installation rules The connections should comply with local electrical code Safety Information In English The equipment must be connected to an earthed mains socket out...

Page 3: ...not be used until a replacement cover is obtained A replacement fuse cover can be purchased from your local our dealer IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN...

Page 4: ...lt an electrician for replacement of the obso lete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the...

Page 5: ...imer of warranty 10 Network security 11 Limitation of liability 11 About Additional Camera Kit option 11 About Secure Communication Kit option 11 About the business intelligence function option 12 Abo...

Page 6: ...ailable Images from up to 32 cameras with the image capture size of 4K 3840 2160 can be saved as video data This recorder also supports the HDMI output to 2 monitors that can display recorded images a...

Page 7: ...7 Introduction continued System Configuration Main monitor HDMI Powered speaker Sub monitor HDMI Sub monitor BNC The sub monitor only displays live images Network camera 32 max Network PC...

Page 8: ...ation compatible cameras and their versions Refer to our support website https i pro com global en surveillance training_support support technical_information for latest information about the compatib...

Page 9: ...Windows 10 Web browser Windows Internet Explorer 11 32 bit CPU Intel CoreTM i7 860 Memory 4 GB or more Monitor 1024 768 pixels or more 24 bit True color or better Network interface 10BASE T 100BASE TX...

Page 10: ...UDING BUT NOT LIMITED TO BELOW 1 ANY LOSS OR DAMAGE INCLUDING WITHOUT LIMITATION DIRECT OR INDIRECT SPECIAL CONSEQUENTIAL OR EXEMPLARY ARISING OUT OF OR RELATING TO THE PRODUCT 2 ANY INCONVENIENCE LOS...

Page 11: ...protect yourself against the above network security risks Use this unit in a network secured by a firewall etc If this unit is connected to a network that includes PCs make sure that the system is no...

Page 12: ...e with the registered face images face matching function The statistical processing for the results of the face matching will also become available and it displays the result on the main monitor conne...

Page 13: ...ock Do not connect disconnect the power plug with wet hands Failure to observe this may cause electric shock Avoid doing anything that can damage the power cord plug Do not damage modify forcefully be...

Page 14: ...operational environment Write errors may occur frequently after around 20000 hours of each HDD operation and head and motor deterioration may occur after around 30000 hours of operation They will reac...

Page 15: ...BTAINED FROM A VIDEO PROVIDER LICENSED TO PROVIDE AVC VIDEO ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA L L C SEE HTTP WWW MPEGLA COM About reboot of this product In the following cases this p...

Page 16: ...es that the respective hard disk drive is faulty which can be recovered by replacing the hard disk drive In the RAID 5 mode it indicates that the respective hard disk drive is the first faulty drive I...

Page 17: ...he recorder Insert a fine stick like a paper clip and keep pressing for more than 5 seconds Decorative cover Inside the front cover HDD bracket screw These are screws to fix the HDD bracket The screws...

Page 18: ...compatible with 10BASE T 100BASE TX or 1000BASE T When the port is being accessed the access indicator green blinks When the port is being linked the link indicator orange lights Camera PC Access ind...

Page 19: ...r with the provided power cord clamp passed through the clamp mount Clamp mount Power cord clamp Pass the power cord clamp accessory through the clamp mount 15 cm 20 cm 5 7 8 7 7 8 inches Tighten the...

Page 20: ...Manager 1 High Operator 2 Viewer 3 Logged out 4 Low When the two or more users at the same level perform the same operation the recorder will be controlled in accordance with the latest operation Defa...

Page 21: ...dispersion of display area on the monitor This is not a malfunction When a function to automatically enlarge the images in the con nected monitor is enabled some part of the images may not be displaye...

Page 22: ...To keep the correct recording set the time periodically or enable the auto time adjustment function on the rear panel terminal or configure the system using the NTP function so as to keep the cor rect...

Page 23: ...only when 4 hard disk drives are installed Input Output Video Video output connector 1 V p p 75 1 BNC Monitor HDMI connector HDMI 2 19 pin type A Main monitor 3840 2160 4K p 30 Hz 3840 2160 4K p 25 H...

Page 24: ...NXS04 WJ NXS04W Secure Communication Kit license for 16 cameras WJ NXS16 WJ NXS16W Secure Communication Kit license for 32 cameras WJ NXS32 WJ NXS32W Additional Business Intelligence Kit WJ NXF02 WJ...

Page 25: ...L1017 4042 PGQP2560VA For Europe and other countries i PRO Co Ltd Fukuoka Japan https www i pro com i PRO EMEA B V UK Branch 1010 Cambourne Business Park Cambridgeshire CB23 6DP Authorised Representa...

Reviews: