Power cord clamp mount
⑯
SIGNAL GND terminal [SIGNAL GND]
Connect this terminal with the SIGNAL GND terminals of
the devices in the system for signal ground. When
operating the recorder and the devices in the system
without signal ground, noise may be produced.
⑰
Power cord inlet [AC IN]
Connect the provided power cord to this inlet. The
power plug of the recorder is 2-prong plug equipped
with a grounding terminal.
How to prevent power cord
disconnection
Fix the power cord at 15 cm to 20 cm {5-7/8 to 7-7/8 inches}
from the connector with the provided power cord clamp
passed through the clamp mount.
①
Clamp mount
Power cord clamp
①
Pass the power cord clamp (accessory) through the
clamp mount.
15 cm ~ 20 cm
{5-7/8 ~ 7-7/8 inches}
②
②
Tighten the power cord at 15 cm to 20 cm {5-7/8 to
7-7/8 inches} from the connector and fix it to the
clamp mount.
Cut the unnecessary part of the power cord clamp as
necessary.
How to use the cable clamp (for
fixing the terminal block cables)
①
①
Insert the cable clamp (accessory) in the cable clamp
fixing hole.
②
②
③
②
Insert the terminal plugs into the Alarm/Control
connector A and B.
③
Bundle the cables of the terminal plugs, tighten them
with the cable tie of the cable clamp (accessory) and
fix them.