60
Configure HTTP alarm notification settings [HTTP alarm]
Configure the settings to notify the PC via HTTP when an event or error occurs.
[Address 1] to [Address 5]
Set the IP address or host name of the HTTP server
for HTTP alarm notification. Up to 5 addresses can be
set.
Available number of characters: 0 - 255 characters
Available characters: Half-width alphanumeric
characters, half-width symbols
Default setting: http://
Input example: http://IP address: Port number, or
http://host name: Port number
https://IP address: Port number, https:// host name:
Port number
[User name]
Enter the user name to access the HTTP server.
Available number of characters: 0 - 63 characters
Unavailable characters: Full-width and half-width
symbols " " " " & "
Default setting: Blank
[Password]
Enter the password to access the HTTP server.
Available number of characters: 0 - 63 characters
Unavailable characters: Full-width and half-width
symbols " " " " & "
Default setting: Blank
Note:
• Basic or Digest authentication is performed
according to the HTTP server's authentication
request.
[Notification data]
Enter the content of the notification to be added after
the HTTP servers set in [Address 1] to [Address 5].
Available number of characters: 0 - 255 characters
Available characters: Half-width alphanumeric
characters, half-width symbols
Default setting: /
By checking the "Alarm", "Emergency recording
input", "Camera/Recorder Error", "HDD/Recording
Error" and "Network error" checkboxes, HTTP alarm
notifications will be sent when the respective event or
error occurs.
Note:
• If you enable the HTTP alarm function, the
authentication information (user name and
password) of the HTTP server may be leaked on
the network when an alarm is notified to the HTTP
server.
• The "Notification data" must be entered with a
slash (/).
• If the "Notification data" is left blank and press the
[OK] button, "/" will be set.
• Example: If "http://192.168.0.100" is set as the
"Address" and "/cgi-bin/comalarm.cgi?CMD=01"
is set as the "Notification data", the HTTP alarm
notification "http://192.168.0.100/cgi-bin/
comalarm.cgi?CMD=01" will be used for the
HTTP alarm notification.