background image

Rigging a BB1 Powerbar

To rig a Powerbar horizontally use the two OMEGA brackets supplied with the bar.

These would have your clamps of choice bolted on to them.

First place the camloc pins in the receptacles either on the top of the powerbar with the levers facing out 

so that a quarter turn clockwise will have them facing in alternate directions as shown.

OPERATING INSTRUCTIONS  -  Page 6

Always secure the Powerbar to the truss,pipe e.t.c. with a safety bond, attached to the bar through the the 

safety points on the top of the bar shown in green.

Always secure the BB1 to the Powerbar through the safety points on the bottom of the bar shown in green.

The Powerbar can also be rigged using a spigot as shown.

Summary of Contents for BB1

Page 1: ...BB1 6 WAY POWERBAR User Manual...

Page 2: ...A MEMORY PROGRAMING A CHASE page 12 page 12 page 14 page 15 page 16 THE TECHNICAL STUFF BB1 TECHNICAL SPECIFICATIONS 6 WAY POWER BAR TECHNICAL SPECIFICATIONS 6 WAY POWER BAR HARDWIRED TECHNICAL SPECIF...

Page 3: ...o the beam for extended periods at a short distance Do not view the beam directly with optical instruments Read this manual before installing powering or servicing the fixture follow the safety precau...

Page 4: ...ing PROTECTION FROM FIRE Do not attempt to bypass thermostatic switches or fuses Replace defective fuses with ones of the specified type and rating only Provide a minimum clearance of 0 1 m 4 in aroun...

Page 5: ...M DMX digital drive It can be submerged and comes with a single cable tted with a high quality 5 pin weatherproof connection The BB1 can be used independently e g as a truss or a set toner It is tted...

Page 6: ...evers facing out so that a quarter turn clockwise will have them facing in alternate directions as shown OPERATING INSTRUCTIONS Page 6 Always secure the Powerbar to the truss pipe e t c with a safety...

Page 7: ...de beside the port number it is attached to 2001 M2 Ports with no attached xtures will be shown as EMPTY 2 Press the button of the xture you wish to Identify PSNLTY ADDR MORE IDENTIFY PRESS 3 Press th...

Page 8: ...on once SEARCHING FOR DEVICES PORT 1 The powerbox will now search out all connected xtures 1001 M2 2006 M2 EXIT 3011 M2 Any xture connected will be shown as an address and mode beside the port number...

Page 9: ...ither the 1 3 or 4 6 button once SEARCHING FOR DEVICES PORT 1 The powerbox will now search out all connected xtures 1001 M2 2006 M2 EXIT 3011 M2 Any xture connected will be shown as an address and mod...

Page 10: ...RESS 4 Press the mode button to change the xture personality OPERATING INSTRUCTIONS Page 10 1 Press either the 1 3 or 4 6 button once SEARCHING FOR DEVICES PORT 1 The powerbox will now search out all...

Page 11: ...GRAPHICAL OVERVIEW MASTER INTENSITY r g R G ode 1 h 8 bit Mode 4 9 ch 16 bit Mode 2 6 ch 16 bit Mode 3 5 ch 8 bit R G r g ODES A GRAPHICAL OVERVIEW r g b r g r g b r g b Mode 5 12 ch 8 bit STROBE CHAN...

Page 12: ...ariable of your memory wich is the master intensity MINT The default value for MINT is 100 intensity full 4 if you wish to alter this value use the UP and DOWN buttons to achieve the desired value 5 W...

Page 13: ...e desired if you require 100 use the DOWN button 7 When happy with the red value press the RED button once Next you are presented with the second colour green GRN default 0 In the same way use the UP...

Page 14: ...MEM 01 button once and you will be returned to the rst parameter master intensity MINT and you can reprogram the memory 2 Using the UP DOWN buttons assign the memory a number DOWN MEM 02 PRESS UP STO...

Page 15: ...1 This will come on automatically 4 Use the UP and DOWN buttons to select the desired memory The memories will come on as you scroll through them 5 To exit the memory If the unit is receiving dmx pres...

Page 16: ...held constant for DOWN WAIT TIME PRESS UP 004s 4 Select the appropriate time in seconds using the up down buttons 5 When happy with the WAIT TIME press the WAIT TIME button once DOWN WAIT TIME PRESS U...

Page 17: ...ption one memory above the one chosen to start the chase The chase will run through all the memories between the memories in the rst and last step DOWN chase end PRESS UP mem 04 10 Choose which memory...

Page 18: ...10mm bolt holes on inner yoke 12mm bolt holes on outer yoke Note unit comes with Omega rigging bracket to accept 12mm bolts 15 volt DC 3 9 amps on full 25 watts total power on full trailing male IP67...

Page 19: ...comes with teo Omega rigging bracket to accept 12mm bolts 90 265 Volt 50 60 Hz 0 75 amps 240 volts 180 watts total power on full 240 volts 20mm x 5mm slow blow 4 amp chassis mounted IP67 6 pin Combine...

Page 20: ...derwater capability folded stainless steel 10 turn camloc fasteners 5 rigging locations bar Note unit comes with teo Omega rigging bracket to accept 12mm bolts 90 265 Volt 50 60 Hz 0 75 amps 240 volts...

Page 21: ...OPERATING INSTRUCTIONS Page 21 1380mm 80mm 80mm 260mm 144mm OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 6 Way Powerbar Dimensions...

Page 22: ...lem as it could be an internal fault If you have the technical knowledge skills you could open up the unit Yes check for loose connections Contact I Pix for more specific help with your problem as it...

Page 23: ...y is working with a 15v output when there is no load connected to it Dmx trouble shooting The obvious It is good practice to connect data line and terminate before switching on device Is the dmx line...

Page 24: ...with no attached xtures will be shown as EMPTY 1 empty 2001 M2 4 empty 3 empty PRESS 2 Press the button of the xture you wish to change the Mode of 3 Press the MORE button once PSNLTY ADDR MORE IDENTI...

Page 25: ...Press the button of the xture you wish to change the Mode of 3 Press the MORE button once PSNLTY ADDR MORE IDENTIFY PRESS RUNTIME CURVE L EXIT softver The BB1contains some usefull internal informatio...

Page 26: ...orized modification improper use or operation outside of Sellers specifications for the product abuse neglect or accident THE ABOVE WARRANTY IS EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL...

Page 27: ...illage Cheshire SK5 7DL Located 4 miles from Manchester airport and the city centre Tel 44 0 161 443 4140 E mail service i pix com www i pix com SERVICE CONTACT DETAILS BB4 USERS MANUAL PAGE 30 BB2 US...

Reviews: