I-PEX CABLINE-UY 20857-0 T-0 Series Instruction Manual Download Page 7

 

CABLINE-UY Connector (Wire Type Plug) Instruction Manual

 

Document No. 

HIM-18037

 

 

 
 

 

7

  / 

7

 

Confidential C                                                                   

注意事項  CAUTION   

冶具は必ず基板と垂直に引き上げてください。

(Fig. 11)

 

” Pushing and Pulling JIG” must be raised vertically from the PCB surface. (Fig. 11) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

【コネクタ取り扱いの注意】  (CAUTION IN CABLE CONNECTOR HANDLING)

 

Fig. 12 のように、矢印方向に常に力が加わるようなケーブルの引き回しを行うと、嵌合外れやコネクタの破損等 
の恐れがありますので、ご注意願います。

 

In the case of Fig. 12, it has possibility to damage to the connector and come off from receptacle connector. 
Especially when operator gives continuous force to the direction (red arrow), the tendency becomes higher. 

    So please take care of handling of harness.

 

 

Prohibited

 

Prohibited

 

Allowed

 

Pushing and Pulling JIG 

PCB 

Fig. 11 

Fig. 12 

Summary of Contents for CABLINE-UY 20857-0 T-0 Series

Page 1: ...FDE09 03 REV 8 CABLINE UY Connector Wire Type Plug Part No 20857 0 T 0 20854 0 E 0 Instruction Manual 1 S20033 January 20 2020 Y Fukumoto T Yamauchi Y Shimada 0 S19022 January 9 2019 Y Imaji K Yufu K...

Page 2: ...plug properly and safely Connector parts No CABLINE UY PLUG 20857 0 T 0 CABLINE UY RECEPTACLE 20854 0 E 0 JIG Pushing and Pulling JIG Fig 1 JIG JIG Fig 2 In mating unmating a special jig shown in Fig...

Page 3: ...Place a cable connector on a PCB connector as shown in Fig 4 Then move connectors left and right and back and forth slightly to make sure the connectors are firmly set How to mate Fig 5 Push the cente...

Page 4: ...t the stopper of the plug The jig should be holding the plug entirely Mating direction Fig 6 b Fig 6 c As shown in Fig 6 b place the plug above the receptacle to align mating direction When the connec...

Page 5: ...nnectors were misaligned as shown in Fig 7 b CAUTION Fig 8 a Fig 8 b Please make sure to set the cable side connector parallel to the board as shown in Fig 8 a If you mate in not parallel condition as...

Page 6: ...f the jig is removed when it is still touching the connector as shown in Fig 9 b the connectors may get unmated or mating may get incomplete How to withdraw cable connector Fig 10 a Slide the Pushing...

Page 7: ...ace Fig 11 CAUTION IN CABLE CONNECTOR HANDLING Fig 12 In the case of Fig 12 it has possibility to damage to the connector and come off from receptacle connector Especially when operator gives continuo...

Reviews: