slowly or stop; when controller stop working, fan also stop
ran.
Components
World brand raw materials. Compliance with EU
standards. All rated temperature of electrolytic capacitors
not less than 105
℃
Smell
No peculiar smell and toxic substances.
Environment Protection
Meet the 2002/95/EC,no cadmium hydride and fluoride
Physical
Measurement DxWxH (mm)
270*185*90
N.G(kg)
3
G.N(kg)
3.6
Color
Blue/Green (optional)
Safety
CE, RoHS, PSE,FCC
EMC
EN61000
Type of Mechanical Protection
IP21
Environment
Humidity
0~90%RH ( no condense)
Altitude
0~3000m
Operating Temperature
-20
℃
~ +40
℃
Storage Temperature
-40
℃
~ +75
℃
Atmospheric Pressure
70~106kPa
10.
Maintenance and Cleaning
10.1 Replacing the Thermal Fuses
Using incorrect thermal fuses may irreparably damage the solar charge controller.
• Only use the thermal fuses included in the scope of delivery
1. Open the solar charge controller as described in section "Opening the solar charge
controller"
2. Remove the broken thermal fuses from the sockets (A and B).
3. Insert new thermal fuses (included in the scope of delivery).
4. Close the solar charge controller as described in section "Closing the solar charge
controller".