I-Michealth HL168JC Instruction Manual Download Page 1

I

I

n

n

s

s

t

t

r

r

u

u

c

c

t

t

i

i

o

o

n

n

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

Automatic  

Wrist Blood Pressure Monitor 

 

 

M

M

o

o

d

d

e

e

l

l

 

 

N

N

o

o

.

.

 

 

H

H

L

L

1

1

6

6

8

8

J

J

C

C

 

 

 
 
 
 

 

1

Summary of Contents for HL168JC

Page 1: ...I In ns st tr ru uc ct ti io on n M Ma an nu ua al l Automatic Wrist Blood Pressure Monitor M Mo od de el l N No o H HL L1 16 68 8J JC C 1...

Page 2: ...ons 06 Device Overview 08 Symbol Definitions 10 Installing Batteries 11 Applying the Cuff 12 Positioning Guide 13 Measurement Procedure 14 Memory Function 16 Storage and Maintenance 17 Troubleshooting...

Page 3: ...spect that you have a medical problem promptly consult your healthcare provider Intended Use This device uses the oscillometric method to automatically measure systolic and diastolic blood pressure as...

Page 4: ...the afternoon to the evening It is on average lower in the summer and higher in the winter 2 Why is it useful to measure blood pressure at home Having one s blood pressure measured by a doctor in a ho...

Page 5: ...ian for proper diagnosis B Variations in blood pressure Individual blood pressures vary greatly both on a daily and a seasonal basis These variations are even more pronounced in hyper tense patients N...

Page 6: ...ranges 15 90 R H or you may get inaccurate readings Wait 30 45 minutes before measurement if you ve just consumed caffeinated beverages or smoked cigarettes Rest at least 5 10 minutes before taking a...

Page 7: ...ult your healthcare professional before using the device This product is not suitable for pregnant women Blood pressure measurements taken with this device are equivalent to those obtained by a traine...

Page 8: ...ct components LCD DISPLAY WRIST CUFF START STOP BUTTON AAA 1 5V ALKALINE BATTERY X 2 BUTTON MEMORY SET BUTTON MODE BUTTON STORAGE CASE Substitution of a component different from that supplied might re...

Page 9: ...e Overview Unit display YEAR DATE TIME MINUTE AFTERNOON TIME MEASURING SYMBOL SYSTOLIC RATE BLOOD PRESSURE UNIT LOW BATTERY SYMBOL DIASTOLIC RATE ERROR SYMBOL MEMORY RECORD NUMBER HEART RATE PULSE SYM...

Page 10: ...ol We suggest you replace all batteries with new ones and make sure the polarities are properly positioned Once pulse is detected the symbol flashes with each pulse beat Pulse Symbol Our suggestion Pl...

Page 11: ...ies into the battery compartment as shown Make sure the polarities and ends are properly positioned Attention y Batteries are hazardous waste Do not dispose of them together with the household garbage...

Page 12: ...the cuff snugly Do not make it too tight Fold the remaining part of the cuff back out of the way Leave approximately 0 4 inch 10 mm between the cuff and the bottom of your hand palm 0 4 inch 10 mm 5...

Page 13: ...results 1 Sit down comfortably with your feet flat on the floor 2 Position the blood pressure monitor on your wrist 3 Place your elbow on the table and rest the back of your hand on the device storage...

Page 14: ...1 2 3 12P 1 P 12 and MINUTE 00 01 02 03 59 as described in Step B above using MODE button to adjust digits and SET button to confirm the entries Taking a measurement A Press SET button to switch from...

Page 15: ...y If the cuff does not stop inflating remove the cuff at once y To stop measurement you may press START STOP button The cuff will deflate immediately after the button is pressed D When the measurement...

Page 16: ...ements C Press MEMORY button again The latest measurement will appear with the recording date and time D Press MEMORY button to read the following measurements in sequence E To stop reading the memori...

Page 17: ...ny parts of the monitor including wrist cuff due to substitution of a component different from that supplied might result in measurement error If any suggestion or service is requested please consult...

Page 18: ...rect positions Cuff has been placed incorrectly Wrap the cuff properly so that it is positioned correctly Did you talk or move during measurement Error Symbol appears when blood pressure value display...

Page 19: ...cover damage caused by misuse or abuse accident the attachment of any unauthorized accessory alteration to the product improper installation unauthorized repairs or modifications improper use of elect...

Page 20: ...t 3 70 0 17 oz 105 5 g Excluding cuff batteries Cuff size 135 195 mm 5 3 7 7 inch Storage Transportation environment Temperature 20 70 C 4 158 F Humidity 90 R H Operation environment Temperature 10 40...

Page 21: ...ygmomanometers Test procedures to determine the overall system accuracy of automated non invasive sphygmomanometers Important Caution Note Read the operating instructions Consult instructions thorough...

Page 22: ...midity should be at least 30 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical com...

Page 23: ...y an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80...

Page 24: ...Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pul...

Reviews: