Hardware Manual
BMS Master 4 / 4.5
Ref.: IR14417 A 15.01.2018
Page 62/76
4, 8
SI+B,
SI-B
Differentially Return–Signal to CON module or to previous ANA-
module (ca. 10kHz)
ANA module, 8 pole connection Top – communication to the next module
Pin
Signal
Description
1, 5
T1, T2
Differentially ISO SPI signal to the next ANA – module
2, 6
Shield
3, 7
EN+T,
EN-T
Differentially stimulation signal to the next ANA module (ca.
10kHz)
4, 8
SI+T,
SI-T
Differentially Return signal from next ANA module (ca. 10kHz)
The single cell voltages are connected to 14 pole connector. The wire gauge should be 0.5
mm².
For the Temperature Measurement in the battery are connected 5 sensors to the SL6 ANA
module. The sensors 1…3 are used for the accurate temperature measure in the battery.
The sensors 4, 5 are used for the second level Hardware detection (Over and under
Temperature). The sensors are connected to the 10 pole connector.
Sensor Types:
- Sensor 2 … 5: VISHAY NTCLE100E3103 with 10 kΩ resistor at 25 °C
Or types with similar temperature characteristic
Second Level detection:
-
Sensor 4 triggers an Under temperature signal at lower than -40 °C,
-
Sensor 5 triggers an Over temperature signal at higher than +90 °C
3.6.8.2
C
ONNECT LESS THAN
12
CELLS
To connect less than 12 cells, the not presented cells must be replaced by shorting to the
connector. The allowed voltage range of the Slave6 A module is describe in chapter
3.6.8.6.
The crimp contacts are not able to use more than 1 wire in one contact; short circuit
connection should be realized outside of the connector. The short circuit wires must be
short as possible, e.g. with isolated shrink hose solder connections.
Summary of Contents for BMS Master 4
Page 73: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 73 76 6 CERTIFICATES...
Page 74: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 74 76...
Page 75: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 75 76...
Page 76: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 76 76...