Hardware Manual
BMS Master 4 / 4.5
Ref.: IR14417 A 15.01.2018
Page 58/76
CON module, 12 pole connector to BMS Master
Pin
Signal
Description
1
VNET
Power Supply from Master, typical 12VDC (9…16)
2, 8
TERM L/H Activation CAN termination resistor 120 Ohm (short Pin 2- 8)
3, 4
CAN H
Signal CAN high, communication to Master
5, 11 FAIL A, B
Differentially error signal line RS485 to Master, only Master 4.5
(second level detection)
6
FAIL_
Static error signal to Master (second level detection)
7
GND
Ground (Minus) from Master
9, 10 CAN L
Signal CAN low, communication to Master
12
SHIELD
CON Modul, 8 pole connector for relay output
Pin
Signal
Description
1, 5
KL30 (+)
Power supply for outputs, (9 … 28V)
2, 3, 4, 8 GND
Ground (Minus)
6
SW1
Output 1
7
SW2
Output 2
CON module, 8 pole connector to 1. SL6 ANA module
Pin
Signal
Description
1, 5
T1A, T2A
Differentially ISO SPI signal to the lowest ANA module
2, 6
SHIELD
3, 7
EN-T, EN+T
Differentially stimulation signal to the lowest ANA module (ca.
10kHz)
4, 8
SI-T, SI+T
Differentially Return signal from the lowest ANA module (ca.
10kHz)
3.6.7.2
M
ECHANICAL
D
IMENSIONS
• Module size 80.5 x 97 x 17 mm;
• For mounting holes for M3-screws, symmetrically arranged in the corners, distances 67
x 83.5 mm
Summary of Contents for BMS Master 4
Page 73: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 73 76 6 CERTIFICATES...
Page 74: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 74 76...
Page 75: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 75 76...
Page 76: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 76 76...