
Hardware Manual
BMS Master 4 / 4.5
Ref.: IR14417 A 15.01.2018
Page 25/76
48.00
2
5
.0
0
54.00
PTSA25-6
1
2
3
4
5
6
K2
K1
S2
S1
LC1
LC2
Compensation 2
Compensation 1
Sense 2
Sense 1
do not connect
3.2.1.1
C
ONNECTION TO THE
MASTER
The picture shows the wiring between the
VAC_PCB board and connector
CN104 on BMS_MASTER.
Wire gauge must not exceed 0.5 mm² (AWG20).
Total wiring length should be kept as short as possible.
Current Direction:
The BMS measuring system interprets a negative current as a discharge current
and a positive one as a charge current. The load wiring has to be installed
accordingly.If necessary the measured current flow direction may be inverted by
interchanging the signal cables pairwise (K1 vs. K2
AND
S1 vs. S2).Attention:
changing only one cable pair may result in sensor damage.
7
V
1
2
3
4
5
6
7
8
S
1
K
1
K
L
3
1
S
2
K2
C
A
N
2
H
C
A
N
2
L
S
h
ie
ld
9
Master04 - CN 104
CAN 2
LiYCY- TP 2x2 0,25mm²
K1 & K2 twisted
S1 & S2 twisted
Current sensor
VAC4645
K
2
1
2
3
4
5
6
K
1
S
2
S
1
LC
1
LC
2
Summary of Contents for BMS Master 4
Page 73: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 73 76 6 CERTIFICATES...
Page 74: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 74 76...
Page 75: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 75 76...
Page 76: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 76 76...