Hardware Manual
BMS Master 4 / 4.5
Ref.: IR14417 A 15.01.2018
Page 21/76
green LED, left
RJ45
Jack
yellow LED, right
link active
speed
3.1.3.9
I
NTERNAL
I
NTERFACES
For software development and test purposes only there are interfaces on the board, which
are accessible only with opened case:
-
JTAG-interface to XC167-processor
-
JTAG-interface to AT91- processor
-
RS232-interface to AT91- processor
-
USB-interface to AT91- processor
These interfaces are of no concern for the user and must not be operated for any purpose.
3.1.3.10
LED
S
There are 5 + 2 LEDs at the front side right of the RS232-jack with software dependent
meanings.
3.1.4.
E
LECTROMECHANICS
The supply- and the I/O-interfaces are realized with the MCP 2.8 mm interconnection
system by TYCO-AMP. The tab housing cavities mate with Junior Power Timer crimp
contacts without single wire seal with maximum wire size of 2.5 mm².
TYCO-AMP order for the connector:
-
TYCO Fem-Cable-Connector 21POL: 1-967625-2
-
TYCO Fem-Cable-Connector 6POL: 1-965640-3
-
TYCO Fem-Cable-Connector 9POL: 1-967621-4
TYCO-AMP order numbers for JPT-contacts spare parts
(loose piece, ‘x’ and ‘y’ depend on material and finish):
-
1.0…2.5 mm²
x-927777-y
-
0.5…1.0 mm²
x-927779-y
-
0.2…0.5 mm²
x-927776-y
-
extraction tool
1-1579007-6
ATTENTION:
The tab housings are not coded. Take care to avoid misconnections of tab housings
with same pin count.
Summary of Contents for BMS Master 4
Page 73: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 73 76 6 CERTIFICATES...
Page 74: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 74 76...
Page 75: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 75 76...
Page 76: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 76 76...