I-CON ProLAST COBALT Installation Instructions Manual Download Page 1

I-CON COBALT

 Manual Exposed Flush Valve 

powered by ProLAST

® 

 Installation Instructions

VLV-FVL-MN3000 Series

• All plumbing should be installed according to applicable state 

and local codes and regulations 

• Before installation of the I-CON flushometer, ensure the water 

closet or urinal fixture, drain line and water supply line are 

properly installed 

• Water supply lines must be sized to allow for appropriate 

water flow for each fixture 

• Flush all water supply lines of any debris before making and 

connections 

• Do not use pipe sealant or plumbing grease on any 

components or couplings with exception to the control stop inlet 

• A smooth jawed or strap wrench should be used for installation 

to prevent damage to the finish of the I-CON flushometer and 

components 

The I-CON flushometer is designed to operate at water pressures 

ranging from 15 to 100psi (103 to 689kPa). The fixture type 

determines the minimum pressure required to the valve. Most 

low consumption water closets are designed to operate with a 

minimum flowing water pressure of 25psi (172kPa).

Flat Head Screwdriver

Smooth Jawed 

Wrench

Pipe Solder

COBALT

 MANUAL EXPOSED FLUSH VALVES

TOOLS NEEDED

PRIOR TO INSTALLATION

LIMITED WARRANTY

TOP EXPOSED

URINAL EXPOSED

REAR EXPOSED

page 1

Strap Wrench

I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com

Pipe Cutter

  11 12 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

3/4" IPS

SUPPLY

  14 18 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

1"  IPS

SUPPLY

  11 12 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

1" IPS

SUPPLY

  11 12 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

3/4" IPS

SUPPLY

  14 18 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

1"  IPS

SUPPLY

  11 12 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

1" IPS

SUPPLY

  11 12 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

3/4" IPS

SUPPLY

  14 18 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

1"  IPS

SUPPLY

  11 12 "  

  2 14 " MIN  

FINISHED WALL

FINISHED FLOOR

  4 34 "±

1

2 "  

1" IPS

SUPPLY

Rev 022719

I-CON Systems, Inc. (I-CON) warrants that its commercial 

manufactured products are made of first-class materials, are 

free from defects, and are made to withstand normal use when 

installed properly.Products have the following warranty periods: 

3 years for COBALT™, COBALT Pro™, and COBALT Connect™ 

faucets and flush valves and I-CON EDGE® gateways. 1 year for 

all other products and decorative finishes. The warranty period 

begins on the date of purchase.
Products should be sent to I-CON at the customer’s expense. 

I-CON will take a reasonable amount of time to determine if the 

product is defective and whether it will be repaired or replaced.

During the warranty period, items will either be (1) repaired 

at no charge using new replacement parts or (2) replaced 

with either a new similar product or one manufactured from 

new or serviceable used parts that is at minimum a functional 

equivalent to the original. The course of action will be 

determined at I-CON’s discretion. Replacement products that 

are installed according to the instructions provided by I-CON will 

assume the remaining warranty of the original product.

The limited warranty is only applicable to the product’s materials 

and workmanship. No claims for labor, transportation, or other 

incidental or consequential costs will be allowed. No extended 

warranties are available. THE SOLE AND EXCLUSIVE REMEDY 

FOR ANY DEFECTIVE PRODUCT IS LIMITED TO REPAIRING OR 

REPLACING THE DEFECTIVE PRODUCT. Before installing and 

using products, the purchaser is responsible to determine the 

products’ suitability and assumes all risks and liabilities related 

to the product.
This warranty only applies to persons and organizations that 

purchase I-CON products directly from I-CON or an authorized 

I-CON representative for the purpose of resale. This warranty 

does not apply to the life of batteries or other consumables.

Summary of Contents for ProLAST COBALT

Page 1: ...8 2 1 4 MIN FINISHED WALL FINISHED FLOOR 4 3 4 1 2 1 IPS SUPPLY 11 1 2 2 1 4 MIN FINISHED WALL FINISHED FLOOR 4 3 4 1 2 1 IPS SUPPLY Rev 022719 I CON Systems Inc I CON warrants that its commercial manufactured products are made of first class materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 years for COBALT ...

Page 2: ... wall Apply thread sealing compound to the male NPT threads of the threaded adapter Thread the control stop onto the threaded adaptor using a smooth jawed wrench Step 1 Step 1 Step 2 Step 3 Slide the threaded adapter onto the water supply pipe Ensure full insertion Sweat solder the threaded adapter to the water supply pipe Step 2 Step 3 OPTIONAL SWEAT SOLDER THREADED ADAPTER INSTALLATION WALL ESCU...

Page 3: ...R FRICTION WASHER VACUUM BREAKER 3 4 VACUUM BREAKER TUBE 1 1 2 VACUUM BREAKER TUBE 1 1 4 VACUUM BREAKER TUBE FRICTION WASHER SPUD ESCUTCHEON Rear Spud Top Spud page 3 I CON Systems Inc for product support call 1 866 730 7192 or visit us online at support i con com Continued Next Column Continued on Next Page FLUSH SUPPLY INSTALLATION Screw the actuator into the valve body Ensure that the sealing r...

Page 4: ... 3 Flush Supply Installation Continued FLUSHING THE SUPPLY LINE Before the water is turned on unscrew the control stop cap from the control stop and turn the adjustment screw all the way CLOCKWISE to ensure that the control stop is closed Remove the flushometer cap using a strap wrench Then remove the trip mechanism ProLAST Step 1 Step 2 Reinstall the flushometer cap WITHOUT the trip mechanism and...

Page 5: ...ed Step 4 page 5 Step 5 I CON Systems Inc for product support call 1 866 730 7192 or visit us online at support i con com Continued Next Column Continued on Next Page Step 8 Reinstall the flushometer cap hand tighten only Over tightening may cause O Ring to pinch Step 7 Remove the flushometer cap and insert the trip mechanism and ProLAST I CON COBALT Manual Exposed Flush Valve powered by ProLAST I...

Page 6: ...but is not to be excessive Once final adjustments have been made reinstall the control stop cap onto the control stop Do not use commercial cleaning compounds Abrasive or chemical cleaners may dull the luster and attack the chrome finish Use mild soap and water and then dry with a clean cloth or towel When cleaning floor tile or fixtures protect the flushometer from any splattering of cleaner Step...

Reviews: