N700E INSTRUCTION MANUAL
2-29
CF2
CF3
CF4
CF1
FW
0
0
0
1
0
0
0
1
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
F01
Frequency
0
0
0
0
CF4 CF3 CF2 CF1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Frequency
F01
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
2.3.4 Frequency Command Source to Input Analog Voltage / Analog Current
Input Terminal Diagram
Programming N700E Parameters
Programming Frequency Set Point
Diagram
CM1
6
P24
5
4
3
2
1
AT
Programming Frequency Command Source to Input Voltage Source or Current Source
On Keypad, program following parameters with corresponding values
Code
Set
Value
Description
A01
1
Frequency Command Source to Input Terminal
C05
13
Set Terminal 5 to AT Operation.
If Closed, Select Current Source. If opened, Voltage Source.
If function 13 is not programmed to any of the terminals on the terminal
strip (C01 ~ C06), frequency setpoint is the sum of current source and
voltage source
Setting Frequency Setpoint
Program following parameters with specified frequency values.
Frequency setpoint follows analog reference (0 ~ 10V / 4 ~ 20 mA) from 0 to 60 Hz. Analog input
settings can be modified using A05 ~ A09.
H
O
OI
L
VR
DC 12V
DC 0~10V
H
O
OI
L
DC 4~20mA
Input Voltage Source
Setup
Input Current Source
Setup