background image

Summary of Contents for HY300SEI

Page 1: ......

Page 2: ...PRINTSPEC EN3000sei 2013v1 2013 MIDLAND POWER INC ...

Page 3: ...is publication is based on the latest product information available at the time of approval for printing No part of this publication may be reproduced without written permission If a problem should arise please contact us by using the contact information at the end of this manual It is important that this manual be read and fully understood before operating the generator set Failure to do so may c...

Page 4: ...tion of Components Pre operation Inspection Fuel Level Check Air Filter Check Operation Using the Generator AC Operation DC Operation Stopping the Generator Maintenance Troubleshooting Specifications Warranty Glossary 5 6 7 8 9 10 11 12 13 14 15 17 22 26 28 31 ...

Page 5: ...y can ignite OPERATING INSTRUCTIONS Operate the generator according to instructions for safe and depend able service Always perform a pre operation inspection before starting the engine Properly clean and maintain the equipment Make sure to read and understand all warning labels Gasoline is a highly flammable and explosive liquid Make sure to refuel in a well ventilated area with the engine stoppe...

Page 6: ...should be done by a professional electrical technician Improper con nections may lead to a fire hazard or damages to the generator set MAINTENANCE SAFETY After any maintenance is performed wash your body immediately us ing soap and clean water Repeated exposure to lubricant may cause skin irritation Do not clean the filter sponge with flammable fluids such as gasoline or explosion may occur Turn o...

Page 7: ...s running in a partially enclosed space If the generator set is stored outdoors check all the electrical compo nents on the control panel before each use Moisture can damage the generator and can lead to an electric shock IDENTIFICATION OF COMPONENTS Rear Cover Choke Rocker Fuel Switch Primer Bulb Maintenance cover Top Maintenance Cover Control Panel Fuel Cap Cover Starter Grip ...

Page 8: ...ture in your area 1 Loosen the cover screws and remove the maintenance cover refer to fig 2 Remove the oil filler cap and wipe the dipstick clean refer to fig Check the oil level by inserting the dipstick into the filler neck without rotating it 3 If the level is low fill to the upper limit of the oil filler neck with the recommended oil 4 Reinstall the maintenance cover and tighten the cover scre...

Page 9: ...ator gas tank 2 Refill the fuel tank if the level is low Refuel carefully to avoid spilling fuel Do no fill above the upper limit mark Refer to Fig CAUTION Gasoline is highly flammable and explosive Keep the engine away from heat spark the open flame Refuel in a well ventilated area with the engine stopped Only handle fuel outdoors Wipe up spills immediately Avoid getting dirt dust or water in the...

Page 10: ...ts such as dust and dirt being drawn through the carburetor into the engine 1 Remove air filter cover and sponge 2 Inspect filter sponge for dirt and debris 3 Clean filter sponge by soaking in gasoline ring out before reinstalling 4 Replace air filter every 24 months or when necessary Screws Maintenance Cover Air Filter Sponge Air Filter Cover ...

Page 11: ...verload indicator light red lights instead set the engine switch to STOP stop the engine at once and then start the engine again RECOIL START 1 Rotate the fuel switch to the ON position according to the arrow direction 2 Flip the engine switch to the ON position 3 Pull the starting grip lightly until resistance is felt then pull briskly to start the engine Refer to Fig WARNING Do not allow the sta...

Page 12: ...nections may cause serious injuries to electrical worker during power outages Additionally the generator may explode or cause fires when the utility power is restored WARNING To prevent electrical shock from faulty appliances the generator should be grounded Limit operation requiring maximum power to 30 minutes Do not exceed the current limit specified for any one receptacle Do not connect the gen...

Page 13: ...ndicator light may briefly illuminate but this is to be expected Once the device starts up the overload indicator light will shut off and the output light will remain green GROUND TERMINAL Before using the generator a ground wire must be connected to the ground terminal Before using the ground terminal consult a qualified electrician Refer to Fig FOR AC OPERATION 1 Ensure all devices are OFF befor...

Page 14: ... DC OPERATION Do not leave generator unattended when charging batteries Stop charging when the voltage of the batteries is above 16V Failure to monitor charge level may result in damage to the battery or personal injury The DC receptacle may be used while the AC power is in use The overloaded DC circuit will trip the DC circuit protector If this happens dis connect the DC load before pushing in th...

Page 15: ...ce and unplug devices from the generator recep tacles 2 Turn the start switch to the STOP position 3 Rotate the fuel switch to the OFF position in the clockwise direction NOTICE Be sure the fuel SWITCH is in the OFF position and the start switch is in the STOP position when stopping transporting and or storing the generator FOR DC OPERATION An overloaded DC circuit excessive current draw by the ba...

Page 16: ...e engine 2 Disconnect the negative black terminal of charging wire from the negative battery terminal 3 Disconnect the positive red terminal of the charging wire from the positive battery terminal 4 Disconnect the charging wire from the DC Receptacle of the genera tor ...

Page 17: ...ct customer service for replacement parts Some of these maintenance techniques can be dangerous and should be performed by a qualified technician To ensure long lasting durability and performance be sure to inspect and main tain your generator based on the schedule below ITEM ACTION EACH USE 1 MONTH 20 HRS 4 MONTHS 50 HRS 6 MONTHS 100 HRS YEARLY 200 HRS ENGINE OIL Check Level Change AIR FILTER Che...

Page 18: ...e sponge Clean air filter sponge in warm soapy water or non flammable detergent Allow to dry before reinserting into generator Dip sponge in clean engine oil and squeeze out all excess oil The engine will produce excess smoke if too much oil is left in the filter Wipe dirt off the air filter cover using a moist rag CHANGING THE ENGINE OIL 1 Set the start switch to the STOP position and make sure t...

Page 19: ... sure the start switch is in the STOP position before drain ing Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed con tainer to your local service station for reclamation Do not throw it in the trash or pour it on the ground Do not use gasoline for cleaning since it is flammable and explo sive under certain conditions L L 2 Oil ...

Page 20: ...ean any dirt and debris around the spark plug base 4 Use a wrench to remove the spark plug refer to fig 5 Visually inspect the spark plug Clean the spark plug with a brush if it is to be reused 6 The spark plug clearance gap should be between 0 7 mm 0 8 mm 0 028 to 0 03 refer to fig 7 Install the correctly gapped spark plug back into the original position Screw Top maintenance cover Ignition Coil ...

Page 21: ...o not drop or strike the generator when transporting 5 Do not place heavy objects on the generator WARNING Gasoline is extremely flammable and explosive under certain conditions Do not smoke or allow flames or sparks in the area STORAGE PROCEDURE 1 Drain fuel remove gas tank cap remove fuel filter and syphon fuel into an appropriate gasoline container Rotate fuel valve to the open posi tion and al...

Page 22: ...rn the starter grip gently This closes the valves so moisture cannot enter TROUBLESHOOTING If the generator still does not start have an authorized Hyundai repair technician diagnose and repair the problem Attempting service or repair without the proper training tools and equipment may cause injury to you and or others It can also damage the generator or lead to hazardous conditions For more infor...

Page 23: ...ce when pulling recoil starter 1 The engine does not have enough oil add oil 2 Air filter element obstructed by debris Clean according to user manual instruc tions on page 18 Difficulty starting Engine re quires many attempts to start 1 Disconnect load before starting 2 Incorrect oil being used Please refer to the oil usage chart on page 27 in your user s manual 3 Fouled spark plug replace with eq...

Page 24: ...ments Wattage consumption Do not exceed the generators maximum peak output Device will not start up 1 Remove all loads reset breaker and check device for defects Do not exceed genera tor rating 2 Ensure device s wattage consumption does not exceed the generator s maximum peak output Engine idle unusually high or low Carburetor in need of tuning For details on how to adjust correctly please contact...

Page 25: ... by debris Clean according to user manual instruc tions on page 18 4 Adjust choke lever according to user manual instructions on page 12 5 Incorrect oil being used or insufficient oil level Always ensure high oil levels and use oil according to oil usage chart in user manual on page 27 6 Fouled spark plug replace with equal or greater quality plug Refer to page 27 in your user s manual for a compl...

Page 26: ...OR 5 3HP 5500RPM 4 Stroke 150CC Hyundai Motor START Manual Recoil and Electric Start OUTLETS Two 120V 21 6A AC One 12V 8 3A DC One USB FUEL CAPACITY 4 5 L MAX AC OUTPUT 2800W FUEL TYPE Unleaded Gasoline Minimum Octane of 87 RUNNING TIME 3 hours 70 NOISE LEVEL 65dB 7m FRAME 33 mm Polypropylene DIMENSIONS 575x330x525 mm WEIGHT 35 kg ...

Page 27: ...COMMENDED OIL USAGE OIL GRADE TEMPERATURE SEASON 5W40 0 below Winter 10W40 20 to 5 Spring Fall 15W40 20 Summer 10W30 25 to 15 All season SPARK PLUG COMPATIBILITY BRAND HY3000SEI NGK CR7HS DENSO U20FPR CHAMPION RZ10YC BOSCH U24BC ...

Page 28: ...hase and does not restart at anytime under any circumstanc es This limited warranty is valid for residential or recreational applications only and only when the generator receives all necessary preventative maintenance as described in the Hyundai Generators Operation Manual The repair or replace ment of a generator will take place within a reasonable period of time during normal business hours All...

Page 29: ...ARRANTY 1 Normal engine alternator wear 2 Damage caused by lack of maintenance as described in the Hyundai manuals or negligence by using improper or impure motor oil coolant or fuel 3 Damage caused by accidents improper installation or storage 4 Damage caused by water ingestion submersion or external water damage 5 Damage or non performance caused by operation of the gen erator set in a marine ap...

Page 30: ...ust be performed by one of our authorized service dealers If you feel your generator is malfunctioning due to a defect or misuse simply contact our customer support center for technical advice a warranty claim or general information Do not return your generator to the place of purchase for repair MIDLAND IN TERNATIONAL INC SHOULD BE CONTACTED TO PROVIDE A CASE NUMBER BEFORE WARRANTY WORK CAN BEGIN...

Page 31: ...er load or short circuit by stopping the flow of electricity between the generator and device DC SOCKET The receptacle used for charging a 12 V battery DIPSTICK It seals off engine oil fill hole and is used for indicating the engine oil level DRAIN PLUG A plug that can be removed to allow the fluid contents of the engine to be drained off ECON SWITCH This system can be described as a load dependen...

Page 32: ...VERLOAD INDICATOR LIGHT If the generator is overloaded or if there is a short circuit in a connected device the overload indicator light red will go ON It will stay ON and after about four seconds the device will shut off and the output indicator light green will go OFF RECOIL STARTER A pull cord is attached to the engine and you pull the T handle attached to the starter cord assembly to spin the ...

Page 33: ...e continued warranty and service support Warranty support cannot be provided without registration from original date of purchase and after transfer of ownership This transfer form must be completed on or before the date that ownership change takes effect Warranty coverage continues from original date of purchase and is not extended by transfer of ownership ...

Page 34: ...34 HY3000sei User Manual ...

Page 35: ...arcode from your product packaging The store date of purchase and product purchase should be clearly visible on the receipt copy YOU MAY ALSO REGISTER ONLINE BY VISITING OUR WEBSITE WWW HYUNDAIPOWER CA If you wish you can confirm your registration by calling customer service at or by email at support hyundaipower ca Please allow one week for mail delivery and processing Please mail all items to Mi...

Page 36: ...36 HY3000sei User Manual ...

Page 37: ...37 HY3000sei User Manual ...

Reviews: