background image

Cause  -  The suction and/or delivery valves are worn out.

-  Presence of foreign matters in the valves, 

which generate bad functioning.

-  Air suction.

-  The seals are worn out.

Re-

pair 

-  Check and/or replace.

-  Check and clean the replace.

-  Check the suction pipe.

-  Check and/or replace the seals.

Fault

Pressure leakage

Cause  -  The nozzle is worn out.

-  The suction and/or delivery valves are 

broken or down.

-  Presence of foreign matters in the valves, 

which generate the valves bad functioning.

-  The setting valve area is worn out.

-  The seals are worn out.

Repair  -  Replace the nozzle.

-  Check and/or replace the valves.

-  Check and clean the valves.

-  Check and/or replace the setting valve area.

-  Replace the seals.

Fault

Noisiness

Cause  -  Air suction.

-  The suction and/or delivery valve springs 

are broken or down.

-  Foreign matters in the suction and delivery 

valves.

-  The bearings are worn out.

-  Extreme liquid temperature.

Repair  -  Check the suction pipes.

-  Replace the valve springs.

-  Check and clean the suction and delivery 

valves.

-  Replace the bearings.

-  Reduce the liquid temperature.

Fault

Water is in the oil

Cause  -  The O-ring casing is worn out.

-  High moisture in the air.

-  The seals are completely worn out.

Repair -  Check and/or replace the O-ring.

-  Replace the oil with double frequency in 

respect of the one suggested.

-  Replace the seals.

Fault

Filtrations of water from the drains 

between casing and head

Cause  -  The seals are worn out.

-  The piston is worn out.

-  The O-ring of the piston cap is worn out.

Fault

When the main switch is turned on the 

machine does not start

Cause  -  Plug not properly connected.

-  Connection panel fuses are burnt out.

Repair  -  Carefully check the plug and the electric cable.

-  Check them and replace them.

Fault

The motor hums but does not start

Cause  -  A phase is missing (in three phase models).

-  Lows voltage.

-  High pressure pump is blocked.

Repair  -  Contact an authorised service centre.

-  Contact an authorised service centre.

-  Contact an authorised service centre.

Fault

The motor stops suddenly or after a 

while

Cause  -  The motor-protecting switch is on beCause 

of insufficient mains voltage.

Repair  -  Check the value of the mains voltage.

-  Contact an authorised service centre.

Fault

When the lance is turned on pressure 

values decrease and increase

Cause  -  The nozzle is either clogged or deformed.

-  Either boiler coil or lance are clogged with 

limestone.

Repair  -  Either clean it or replace it.

- Descaling.

Fault

To much vibrations at the delivery

Cause  -  The pressure tank is run down.

-  The valve are worn out or dirty.

Repair -  Check the pressure in the tank.

-  Check and/or replace.

Fault

The pump does not reach the fixed pressures

Cause  -  The pump sucks air.

-  The valves are worn out.

-  The setting valve area is worn out.

-  The nozzle is unsuitable or worn out.

-  The seals are worn out.

Repair  -  Check the suction pipes.

-  Check and/or replace.

-  Contact an authorised service centre.

-  Contact an authorised service centre.

Fault Irregular pressure fluctuations

EN

18

Summary of Contents for HY150HPW-1

Page 1: ...WARNING read the instructions carefully before use HY150HPW 1 PRESSURE WASHER Instruction Manual ...

Page 2: ...fig A Depending on the model there are differences in the scopes of delivery DESCRIPTION OF THE MACHINE ...

Page 3: ...3 Diesel Detergent ...

Page 4: ...4 INSTALLATION fig C fig B fig D fig E fig F fig G min 30 l min max 1 MPa optional 5 40 C 1 2 inch 13 mm ...

Page 5: ...5 5 STARTING UP OPTIONAL OPTIONAL spread pattern fig I pressure pressure 1 2 3 4 fig H spread pattern pencil jet ...

Page 6: ...6 Diesel Diesel 4 4 5 5 fig L 1 1 2 2 3 3 6 6 7 7 ...

Page 7: ...NO NO min 120 A 3B A min 20 cm min 7 9 inch OK B 7 fig M ...

Page 8: ...H 2 O WATER DIAGRAM 8 ...

Page 9: ...LKX_LP_3Ph_220V LKX_XP_1Ph LKX_XP_3Ph 1 Ph NPX XP 1 Ph NPX XP 3 Ph ELECTRIC DIAGRAM 9 ...

Page 10: ...ays disconnect the electricity and water supplies on completion of every job 03 WARNING Do not use the machine if a supply cord or important parts of the machine are damaged e g safety devices high pressure hoses trigger gun 04 WARNING This appliance has been designed for use with the detergent provided or the detergent specified by the manufacturer such as a neutral shampoo based on biodegradable...

Page 11: ...e 18 WARNING Never start the high pressure cleaner without first completely unwinding the high pressure hose 19 WARNING When winding and unwinding the pipe take care not to cause the high pressure cleaner to overturn 20 WARNING Before unwinding or winding the hose switch the machine off and release the pressure in the hose itself switching off 21 WARNING Risk of explosion Do not spray flammable li...

Page 12: ...upply Open the water supply WARNING symbol machinenotsuitable for connection to the potable water mains The cleaner can only be connected to the wa ter mains if the water mains is separated by a backflow preventer Make sure that the hose is at least Ø 13mm 1 2 inch and that it is rein forced WARNING Water that has flown through backflow preventers is considered to be nonpotable IMPORTANT Only clea...

Page 13: ...em hasn t to be faced when the ma chine operates outdoor but when it s installed indoor the following recommendations must be followed The chimney path must be always in ascent straight vertical if possible and preferably not exceeding a 5 m lenght The exit of the chimney must be sheltered to avoid the dripping of rain and to allow the exaust flow The chimney section A must be 3 times the outlet c...

Page 14: ...to place by hand without the aid of tools Connect the water supply hose to the snap connection The hose must have an inside diameter of at least 13 mm 1 2 Connect the high pressure hose to the pump s outlet pipe Press the high pressure hose coupling fully down and then screw into place by hand without the aid of tools Connect the high pressure hose to the gun Turn the water tap fully on The water ...

Page 15: ...ave the stand by mode active for more than 5 minutes At the end of the operation set the switch to OFF Activate hand spray gun until device is pressure less if fitted Machines equipped with delayed low voltage Total Stop with intelligent switch off When the machine is working by releasing the gun lever after approximately 15 seconds the motor stops automatically to prevent component wear during th...

Page 16: ...ct the gun from the high pressure line and place its free end in the drum in order to form a closed cir cuit and draw the solution into the machine for at least 10 minutes The delivery end of the line should discharge into a canvas or mesh bag so that the scale removed is not re turned to the circuit Then restore the normal connection and rinse with plenty of cold water This operation should be ca...

Page 17: ...aning operations to which the operative components may be subjected Repairs under this guarantee include replacement of defective parts exclusive of packing and postage car riage The warranty shall not cover replacement of the machine or extension of the guarantee resulting from a breakdown The manufacturer declines all responsibi lity for damage to persons or property caused by bad installation o...

Page 18: ...and head Cause The seals are worn out The piston is worn out The O ring of the piston cap is worn out Fault When the main switch is turned on the machine does not start Cause Plug not properly connected Connection panel fuses are burnt out Repair Carefully check the plug and the electric cable Check them and replace them Fault The motor hums but does not start Cause A phase is missing in three pha...

Page 19: ...n pipe is clean Replace the line filter Replace it Replace it Contact an authorised service centre Check the positioning Replace it Fault Water is not hot enough Cause Poor boiler performance Boiler coil clogged with limestone Re pair Clean burner nozzle filter Clean fuel filter Check diesel pump pressure Descaling Fault Too much smoke from the chimney Cause Combustion is not correct Impurities or...

Page 20: ...20 ...

Page 21: ...y m s2 2 2 Arm vibrations A weighted r m s acceleration value to which the operators arms are subjected in m s2 ValuesaccordingtostandardEN 60335 2 79 Water connection 40 C Supplytemp max 30 l min Supplyrate min 1MPa SupplyPressure max 21 Detergent tank capacity ...

Page 22: ...ns andthestandardsEN Declares under its responsability that the machine GENPOWER LTD Isaac Way Pembroke Dock Pembrokeshire SA72 4RW Technicalbookletat GENPOWER LTD Isaac Way Pembroke Dock Pembrokeshire SA72 4RW 29 10 20 Roland Llewellin Managing Director PRODUCT HOTHIGH PRESSUREWASHER MACHINE MODEL HY150HPW 1 2006 42 EC 2009 127 EC 2014 30 EU 2000 14 EC 2005 88 EC 2011 65 EU 2014 68 EU EN60335 1 E...

Page 23: ...cod 7 700 0551 rev 00 03 2020 ...

Page 24: ...embroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by GENPOWER LTD for The United Kingdom Ireland Licensed by Hyundai Corporation Korea ...

Reviews: