background image

Nozzle

Diesel tank

Detergent tank

Pilot lights:

Pilot lights: DIESEL shortage (OPTIONAL)

A:  Motor pump ON green pilot light

B: Leak pilot light

 - flashes when the pistol lever is repeatedly

operated in a short time or when a leak occurs

in the high pressure circuit. Remove the leak,

referring to an authorized service centre.

 - remains ON when the machine is left in

stand-by for over 20 minutes.

Switch on and off the motor pump switch.

C: Burner switch

 - flashes when the gasoil tank is empty; the

burner is stopped. Refuel.

 -  remains ON when the burner switches on.

> INSTALLATION AND START-UP

(fig. 

A

)

FILLING UP WITH FUEL

Information on the type of diesel fuel to be used:

Diesel for transport uses and without additives. 

Fill the tank with the fuel indicated on the 

technical data plate (Diesel)

Avoid that the tank is empty when the machine is 

running in order not to damage the fuel pump.

 WARNING: Incorrect fuel shall not used as they as

provide hazard.

FILLING UP WITH DETERGENT

the detergent tank with the suggested products, su-

itable for the kind of washing to be carried out.

 WARNING: Make use only of liquid detergent, do not 

absolutely use acid or too much alkaline products. We

suggest you to make use of our products, which have

been studied for the use with washer machines.

> INSTALLATION

(fig. 

CDEFG

)

- Check that the master switch is turned to

“OFF” and that the water filter is fitted into

the pump’s inlet pipe.

-  Screw the snap connection into place by hand, 

without the aid of tools.

- Connect the water supply hose to the snap

connection. The hose must have an inside 

diameter of at least 13 mm (1/2”).

- Connect the high pressure hose to the pump’s

outlet pipe. Press the high pressure hose

coupling fully down and then screw into place

by hand without the aid of tools.

-  Connect the high pressure hose to the gun.

- Turn the water tap fully on. The water

temperature absolutely must be below 40°C.

IMPORTANT: The washer machine has to

operate with clean water in order to avoid any

damages to the washer machine itself.

- Release the gun safety catch and keep the

trigger pressed, allowing the water to flow until 

all the air has been expelled.

-  Fit the lance into the gun.

-  Fit the nozzle into the lanxce.

-  Connect the plug to the power socket.

> 1ST START-UP

When starting up for the first time or after a long pe-

riod out of use, connect the intake line only for a few 

minutes so that any dirt is vented from the delivery 

outlet 

> START-UP

(fig. 

H

)

- Whenever using the high-pressure cleaner, users are

urged to hold the gun in the correct position, with one 

hand on the grip and the other on the spray rod.

-  To start the machine, press the gun trigger

and at the same time turn the master switch to 

“ON”

> TO WASH WITH HOT WATER

(fig. 

A

)

- turn the burner switch and select the desired

temperature setting. 

- To add detergent or disinfectant to the water

jet, open the regulator to the setting for

the quantity required as described in the

“DETERGENT SUCTION” section.

 WARNING: In case of operation indoors,

adequate ventilation and gas venting must be

assured.

> THERMOSTAT SET ABOVE 100 ° C: USE WARNINGS.

EN

14

Summary of Contents for HY150HPW-1

Page 1: ...WARNING read the instructions carefully before use HY150HPW 1 PRESSURE WASHER Instruction Manual ...

Page 2: ...fig A Depending on the model there are differences in the scopes of delivery DESCRIPTION OF THE MACHINE ...

Page 3: ...3 Diesel Detergent ...

Page 4: ...4 INSTALLATION fig C fig B fig D fig E fig F fig G min 30 l min max 1 MPa optional 5 40 C 1 2 inch 13 mm ...

Page 5: ...5 5 STARTING UP OPTIONAL OPTIONAL spread pattern fig I pressure pressure 1 2 3 4 fig H spread pattern pencil jet ...

Page 6: ...6 Diesel Diesel 4 4 5 5 fig L 1 1 2 2 3 3 6 6 7 7 ...

Page 7: ...NO NO min 120 A 3B A min 20 cm min 7 9 inch OK B 7 fig M ...

Page 8: ...H 2 O WATER DIAGRAM 8 ...

Page 9: ...LKX_LP_3Ph_220V LKX_XP_1Ph LKX_XP_3Ph 1 Ph NPX XP 1 Ph NPX XP 3 Ph ELECTRIC DIAGRAM 9 ...

Page 10: ...ays disconnect the electricity and water supplies on completion of every job 03 WARNING Do not use the machine if a supply cord or important parts of the machine are damaged e g safety devices high pressure hoses trigger gun 04 WARNING This appliance has been designed for use with the detergent provided or the detergent specified by the manufacturer such as a neutral shampoo based on biodegradable...

Page 11: ...e 18 WARNING Never start the high pressure cleaner without first completely unwinding the high pressure hose 19 WARNING When winding and unwinding the pipe take care not to cause the high pressure cleaner to overturn 20 WARNING Before unwinding or winding the hose switch the machine off and release the pressure in the hose itself switching off 21 WARNING Risk of explosion Do not spray flammable li...

Page 12: ...upply Open the water supply WARNING symbol machinenotsuitable for connection to the potable water mains The cleaner can only be connected to the wa ter mains if the water mains is separated by a backflow preventer Make sure that the hose is at least Ø 13mm 1 2 inch and that it is rein forced WARNING Water that has flown through backflow preventers is considered to be nonpotable IMPORTANT Only clea...

Page 13: ...em hasn t to be faced when the ma chine operates outdoor but when it s installed indoor the following recommendations must be followed The chimney path must be always in ascent straight vertical if possible and preferably not exceeding a 5 m lenght The exit of the chimney must be sheltered to avoid the dripping of rain and to allow the exaust flow The chimney section A must be 3 times the outlet c...

Page 14: ...to place by hand without the aid of tools Connect the water supply hose to the snap connection The hose must have an inside diameter of at least 13 mm 1 2 Connect the high pressure hose to the pump s outlet pipe Press the high pressure hose coupling fully down and then screw into place by hand without the aid of tools Connect the high pressure hose to the gun Turn the water tap fully on The water ...

Page 15: ...ave the stand by mode active for more than 5 minutes At the end of the operation set the switch to OFF Activate hand spray gun until device is pressure less if fitted Machines equipped with delayed low voltage Total Stop with intelligent switch off When the machine is working by releasing the gun lever after approximately 15 seconds the motor stops automatically to prevent component wear during th...

Page 16: ...ct the gun from the high pressure line and place its free end in the drum in order to form a closed cir cuit and draw the solution into the machine for at least 10 minutes The delivery end of the line should discharge into a canvas or mesh bag so that the scale removed is not re turned to the circuit Then restore the normal connection and rinse with plenty of cold water This operation should be ca...

Page 17: ...aning operations to which the operative components may be subjected Repairs under this guarantee include replacement of defective parts exclusive of packing and postage car riage The warranty shall not cover replacement of the machine or extension of the guarantee resulting from a breakdown The manufacturer declines all responsibi lity for damage to persons or property caused by bad installation o...

Page 18: ...and head Cause The seals are worn out The piston is worn out The O ring of the piston cap is worn out Fault When the main switch is turned on the machine does not start Cause Plug not properly connected Connection panel fuses are burnt out Repair Carefully check the plug and the electric cable Check them and replace them Fault The motor hums but does not start Cause A phase is missing in three pha...

Page 19: ...n pipe is clean Replace the line filter Replace it Replace it Contact an authorised service centre Check the positioning Replace it Fault Water is not hot enough Cause Poor boiler performance Boiler coil clogged with limestone Re pair Clean burner nozzle filter Clean fuel filter Check diesel pump pressure Descaling Fault Too much smoke from the chimney Cause Combustion is not correct Impurities or...

Page 20: ...20 ...

Page 21: ...y m s2 2 2 Arm vibrations A weighted r m s acceleration value to which the operators arms are subjected in m s2 ValuesaccordingtostandardEN 60335 2 79 Water connection 40 C Supplytemp max 30 l min Supplyrate min 1MPa SupplyPressure max 21 Detergent tank capacity ...

Page 22: ...ns andthestandardsEN Declares under its responsability that the machine GENPOWER LTD Isaac Way Pembroke Dock Pembrokeshire SA72 4RW Technicalbookletat GENPOWER LTD Isaac Way Pembroke Dock Pembrokeshire SA72 4RW 29 10 20 Roland Llewellin Managing Director PRODUCT HOTHIGH PRESSUREWASHER MACHINE MODEL HY150HPW 1 2006 42 EC 2009 127 EC 2014 30 EU 2000 14 EC 2005 88 EC 2011 65 EU 2014 68 EU EN60335 1 E...

Page 23: ...cod 7 700 0551 rev 00 03 2020 ...

Page 24: ...embroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by GENPOWER LTD for The United Kingdom Ireland Licensed by Hyundai Corporation Korea ...