COOLING SYSTEM
10-7
3. Installing cooling system
3.1 Installing water pump, water pump pulley and V-belt
Installing water pump, water pump pulley and V-belt
CAUTION
Inspect and adjust the V-belt every 200 hours of oper-
ation.
Depending on the operating condition, inspecting and
adjusting interval may shorten.
Crack, extension,
wear, damage
Crack,
deformation,
damage
Replace
Replace
Water pump and
crankcase fixing bolts (×5)
18.1 ± 3.4 N·m
{1.85 ± 0.35 kgf·m}
[13.4 ± 2.5 lbf·ft]
Water pump and
water pump cover fixing bolts (×3)
9.8 ± 1 N·m
{1 ± 0.1 kgf·m}
[7.2 ± 0.7 lbf·ft]
32.4 ± 2 N·m
{3.3 ± 0.2 kgf·m}
[23.9 ± 1.4 lbf·ft]