Chemical dosing
System Filter– 6 720 803 839 (2014/03)
▶ Using a suitable spanner open the isolation valves (If the
filter is used on a sealed system, recharge the system to
correct working pressure).
Fig. 15
5
Chemical dosing
▶ Remove the "quick dose" air vent with a standard radiator
key.
The built-in, one-way valve will prevent water from
escaping.
Fig. 16
▶ Attach the chemical adaptor and feed in the chemical.
▶ Wait five seconds before removing the adaptor.
Fig. 17
▶ Replace the quick dose air vent [1].
▶ Allow the system to circulate for 30 seconds.
Fig. 18
The adaptor on market leading chemical
additives, either liquid or concentrate form,
will fit onto the "quick dose" air vent.