background image

Subject to change without notice.

Edition: 26 Feb. 2020      Ver. A0      Page 1/7

0s ~ 1h, +∞ (selectable)

Easy-on-the-eye operation which makes the light turning on/off less uncomfortable 

DIP switch offers multiple current selections for different luminaire requirements

Tri-level dimming control based upon occupancy (also known as corridor function)

TM

5-Year Warranty

Input current
Input power

0.15
31W (Max.)

20s

Warming-up

10% / 20% / 30% / 50%

Stand-by period

Stand-by dimming level

Sensor OFF / 50% / 75% / 100%

Daylight threshold

Hold time

Sensitivity

Setting adjustments:

5s ~ 30min (selectable)
2 ~ 50 lux, disabled

HEC9025   HEC9025/I

Detached Version with Tri-level Control / Photocell Advance

TM

 

SensorDIM

TM

 - Integrated HF Sensor and LED Driver 

Applications

Occupancy sensor and constant current LED driver, 2-in-1. 

Suitable for building into the fixture for:

     Office / Commercial Lighting

     Classroom

     Meeting Room

Use for retrofit and new luminaire designs/installations

Features

IP20

RED

EMC standard (EMC)
Safety standard (LVD)

Abnormal protection
Certification

Dielectric strength 

Output short-circuit protection

Semko, CB, CE , EMC, RED, RCM

Input

output: 3750VAC / 5mA /1min

Technical Data

Input Characteristics 

Safety and EMC

Off load voltage
Power factor
Efficiency
Output current

350/500/550/700/750/900mA

55V 

85% (Max.)

Driver Data

Tc: +80

O

Operation temperature
Case temperature (Max.)

Ta: -20

O

C ~ +50

O

C

Environment 

IP20  

IP rating

Sensor Data

Model No.

30

O

 ~ 150

O

<0.2mW

5.8GHz +/- 75MHz

High Frequency (microwave) 

Sensor principle 

Operation frequency

Transmission power
Detection range
Detection angle

Max. (

 

O

 

x H) 12m x 6m

Model No.

220~240VAC 50/60Hz 

Mains voltage

HEC9025   HEC9025/I

HEC9025  HEC9025/I

>0.9

Special photocell to measure and differentiate natural light from LED light from behind the fixture cover (HEC9025/I)

Photocell Advance

EN55015, EN61547, EN6100-2/3

EN61347-1, EN61347-2-13

, SELV

Summary of Contents for SensorDIM HEC9025

Page 1: ...r Office Commercial Lighting Classroom Meeting Room Use for retrofit and new luminaire designs installations Features IP20 RED EMC standard EMC Safety standard LVD Abnormal protection Certification Di...

Page 2: ...Current Model In rush Current Imax Pulse Time HEC9025 48A 40 s HEC9025 I 48A 40 s Conversion table for max quantities of drivers on other types of Miniature Circuit Breaker manufactures datasheet for...

Page 3: ...some areas which require a light change notice before switch off The sensor offers 3 levels of light 100 dimmed light off and 2 periods of selectable waiting time motion hold time and stand by period...

Page 4: ...lection All values settings in RED are valid for 20 seconds Shift Button Press the buttons to select light output at 80 at initial 10 000 hours or 100 Power output 1 Press button Shift the red LED is...

Page 5: ...me 5min stand by time stand by dimming level 30 the steps should be Press button Start button 100 Disable Shift 5min Shift 30 Memory By pointing to the sensor unit s and pressing Apply all settings ar...

Page 6: ...Threshold Set the level according to the fixture and environment The light will not turn on if ambient lux level exceeds the daylight threshold preset Please note that the ambient lux level refers to...

Page 7: ...tronik com download knowledge Introduction of Photocell Advance 2 Regarding precautions for microwave sensor installation and operation please kindly refer to www hytronik com download knowledge Micro...