background image

Subject to change without notice.

Edition: 26 Feb. 2020      Ver. A0      Page 3/7

Intelligent Photocell (daylight detection prior to motion detection)

2

The built-in photocell will also automatically turn off the light when the ambient natural light exceeds the programmed lux level for 
more than 5min, regardless of whether motion is detected or not. This feature can be disabled if it is required that the fixture stays at 
dimmed level during absence.

With insufficient natural light, the sensor 
switches on the light automatically when 
presence is detected. 

With sufficient natural light, the light 
does not switch on when presence is 
detected.

The sensor switches off the light when 
natural light is sufficient, even with 
presence.

5

0

12

Detection Pattern

Ambient daylight 

threshold

One-Key
Commissioning

Photocell

Intelligent

Rotary Switch 

Grouping

Functions and Features

Photocell Advance

TM

868

FSK mode

Tri-level Control (Corridor Function)

1

Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas which require a light change notice 
before switch-off.  The sensor offers 3 levels of light: 100%-->dimmed light (natural light is insufficient) -->off; and 2 periods of 
selectable waiting time: motion hold-time and stand-by period; Selectable daylight threshold and freedom of detection area.  

Sensor

Sensor

min 6m

Distance Recommended between Sensors

Pay attention: The RF signal could be affected by big metal 
plate & wireless devices such as GSM mobile antenna, strong 
Wifi signal, ultra high-voltage cable which emits frequent 
electromagnetic waves radiation, which may interfere with the 
RF transmission and communication! Please always check the 
application environment before mass installation!

We recommend the mounting distance between sensors to be 
more than 6m to avoid sensors from being false-triggered.

Summary of Contents for HMW38/RF

Page 1: ...A capacitive 1200W resistive Capacitive Operation temperature Ta 20 O C 50 O C Environment IP65 IP rating 20s Warming up Technical Data Mechanical Structures and Installations For more details please...

Page 2: ...RF antenna Rotary switch Infrared remote receiver 1 10V 1 10V L N N L Installation hole 71 5 4 2 37 5 38 3 25 11 8 78 2 87 HC034RF 1 10V output RF grouping by rotary switch or remote control C Attach...

Page 3: ...otary Switch Grouping Functions and Features Photocell Advance TM 868 FSK mode Tri level Control Corridor Function 1 Hytronik builds this function inside the motion sensor to achieve tri level control...

Page 4: ...aximum lifetime of the relay 3 RF Grouping by Rotary Switch Maximum 15 channels Noted channel 0 is not for fast grouping and sensors can only be grouped by remote control Transceiver Receiver 15 chann...

Page 5: ...e Semi auto function is disabled ON OFF Power output Press the buttons to adjust the light brightness during hold time Load Indication The light will flash ONCE rapidly after receiving the commamd fro...

Page 6: ...trol please refer to steps below Short press Learn Erase button on RC to activate pairing mode and the receiver unit starts to beep once every second for 3min Note up to 30 units can be paired Short p...

Page 7: ...ing precautions for microwave sensor installation and operation please kindly refer to www hytronik com download knowledge Microwave Sensors Precautions for Product Installation and Operation 2 Regard...

Reviews: