Troubleshooting Flow Chart
Uc (430
‐
470 MHz)
24
6.1.3
No
M
odulation
S
ignal in
T
ransmission
No
Yes
Yes
MIC inputs normally?
Check MIC
No modulation signal
in transmission
CODEC audio input
(MICN2/MICP2) is normal?
CODEC output (R202,
R204) is normal?
Refer to FGU diagram
for repairing
information
No
Check whether U401
works normally
No
Yes
Completed
Does CODEC send data to
SCT3928 (SIDI signal)?
CODEC is abnormal
or damaged
No
Yes
Does SCT3928 send
data back to CODEC
(SIDO signal)?
CODEC is abnormal
or damaged
No
No
MCU controls
SCT3928 normally?
SCT3928 is abnormal
or damaged
Yes
Yes
CODEC power supply and
reset signals are normal?
Check MCU and
related LDO
No
Yes