S902/3
10. Take nozzle. The totaliser display will
show FUELLING and the pump will
start. When main display shows 000000
dispense precisely 20 litres of fuel
(using a measure can).
The main display will show pulses
clocking up.
11. Hang the nozzle back into the holster.
12. If the totaliser display shows
CALIB OK
press the calibration button for two
seconds to return to normal operation.
The Alpha dispenser is now calibrated.
If the totaliser shows
CAL FAIL
or
ERROR
press the calibration button for
two seconds to return to normal
operation. The Alpha dispenser has
NOT
been
calibrated.
Repeat
calibration procedure.
20L