MAINTENANCE
97
5. Open the vent valve on the liquid level indicator.
6. Open the tank fuel valve.
7. Open the valve on the end of the supply hose.
8. Watch for a discharge from the vent valve on the
liquid level indicator. When a cloud of visible vapor
appears, the tank is full. Do not fill the LPG tank
more than the maximum level indicated by the liquid
level indicator. Immediately close the valve at the
end of the hose.
9. Close the vent valve.
10. Close the fuel valve on the tank.
11. Disconnect the supply hose.
12. Stop the pump.
13. Close liquid outlet valve and by--pass return valve
on the storage tank.
Gasoline Or Diesel Fuel
WARNING
When fuel is added, keep the funnel or fuel nozzle in
contact with the metal of the fuel tank to reduce the
possibility of static electric sparks. Clean any spilled
fuel.
1. Remove the fuel cap. Make sure the fuel tank is filled
with the correct fuel for the type of engine in the lift truck.
Clean the fuel cap.
2. Replace the fuel cap.