iRIS 350FX Reference Manual V1.50
17
HyQuest Solutions (NZ) Ltd
- PO Box 9466, Hamilton, New Zealand Tel: +64 7 857-0810 Email: [email protected]
Configuration Menus
All the configuration can be done by connecting the device using iLink 2012. Once the iRIS is connected to
your computer, open up iLink 2012 and click on the ‘Quick Connect’ button. Select the COM port from the
drop down menu and set the baud rate as 115200. When the device is connected successfully, click on the
General option under the Configuration tab to see the configuration settings for the device.
General
Site Name:
This setting is used to enter a name for the site that will be displayed on the main title screen of the LCD.
Note that the maximum length of the site name is fixed at 19 characters.
PIN Code:
Enter a security PIN code between 0 and 9999. This PIN code is used to restrict access to specific LCD screens.
If the PIN code is set to 0 (factory default) then only the four status and the totaliser (view only) LCD screens
are accessible.
UTC Offset:
Enter the UTC offset in this column.
Date Format:
This option is used to select the date format as used throughout the iRIS (LCD screens and configuration
menus).