© 2022 HyQuest Solutions
20
Technical Data
7
Technical Data
Power
Operating Voltage
12 V DC Nominal
Recommended
Battery
12 V DC Sealed Lead Acid (38 Ah)
Low Battery cut-out
10 V DC
Battery
recharge
recovery
12 V DC
Maximum
battery
voltage
14.4 V DC
Operation Range
§
Up to 40 m (130ft) of water pressure head
§
(Special request: up to 50 m (160ft) of water pressure head)
Electronics Quiescent
12 mA (HS40AFC) + 5 mA (WL3100)
Compressor Current
20 Amps for 30 secs every 6 hrs (black Thomas compressor)
26 bubbles/min @ 10mH20) (averages to about 28mA)
(Previous blue ARB compressor drew 30A)
Average
battery
consumption
45 mA (with bubble rate set to 26 bubbles/min @ 10 mH
2
0)
Solar
A small 10 Watt solar panel is sufficient to keep the battery fully charged
Maximum
Tank
/
Purge Pressure
750 kPa (110 psi) [±20 %]
Minimum
Pump
/
Purge Pressure
400 kPa (58 psi) [±20 %]
Differential Pressure
Regulator
20 kPa to 35 kPa (3 psi to 5 psi)
Bubble Rate
Adjustable from 0 to 45 bubbles / min
Transducer Pressure
Connection
1/4 inch tube
River Line Connection 3/8 inch tube (or optional 1/4 inch tube), Dual orifice (2) × 3/8 inch tube (or optional 1/4
inch tube)
Max River-line Length 200 m (600 ft) using 3/8 in OD and 1/8 ID tubing
Summary of Contents for HS40C
Page 1: ...HS40C User Manual 07 2022 01 00 000...
Page 7: ...2022 HyQuest Solutions 7 Introduction...
Page 16: ...2022 HyQuest Solutions 16 Maintenance 4 2 Filter Maintenance...
Page 17: ...2022 HyQuest Solutions 17 Maintenance Note Reverse step 4 to step 1 to re assemble...
Page 35: ...2022 HyQuest Solutions 35 Appendices HS40 Compact DO Typical Installation...
Page 37: ...www hyquestsolutions com 2022 HyQuest Solutions 05 10 2022...