background image

ARAG

®

Series 466 Console

Operating Instructions and Parts Manual

Form 1481

7-03

Description

All part numbers include: power cables, 10' extension
cable, 16.5' boom section output cables, pressure gauge,
connection hose and fittings.

Part Number

Sections

Gauge

4665-3-OP100-3

3

100 psi

4665-3-OP300-3

3

300 psi

4665-5-OP100-5

5

100 psi

4665-5-OP300-5

5

300 psi

Series 466 Console

These sprayer consoles allow the operator to 
monitor and control boom pressure and control each 
boom section. These controls can be easily mounted in 
the sprayer and tractor cabs. Control valves are kept on 
the sprayer frame.

Features:

• Sealed switches

• High brightness LED indicators

• Master valve and pressure regulating switches

• General protection fuse, automotive type

• Switches tested to last more than 100,000 cycles

• 12 VDC operation

• Liquid-filled pressure gauge, 2.5" diameter with rear connection

 

Summary of Contents for ARAG Series 466

Page 1: ...OP300 5 5 300 psi Series 466 Console These sprayer consoles allow the operator to monitor and control boom pressure and control each boom section These controls can be easily mounted in the sprayer a...

Page 2: ...in Fig 6 to the console Connect the other end to the end cable Ref D in Fig 6 and bring the end cable to the point where the control unit is to be installed 4 Route the wiring so that it cannot come...

Page 3: ...ircuits do not connect the power supply cable until the installation has been completed WARNING Make sure that the voltage of the tractor battery is the same as that of the switch box 12Vdc Installati...

Page 4: ...total amp draw capability of 10 amps WARNING Modifying cable harnesses will void the warranty Three wire boom section valves motorized ball valves 1 See Fig 4 for wiring schematic 2 Use standard flat...

Page 5: ...with electrical tape Two wire regulating valves 1 Use the 466 series console controls regulating valves by reversing polarity 2 Use cable marked P 3 Use standard flat spade connectors to insert into t...

Page 6: ...e not working 3 The switches are on OFF but the valves are open 4 The pressure regulating valve works in the opposite direction CAUSE Connectors not connected Fuse blown No power supply Power supply c...

Page 7: ...66550 230 Number of Sections N A 3 5 3 5 Description power cable extension cable extension cable boom section cable boom section cable Meters 1 3 3 5 5 Feet 4 10 10 16 5 16 5 SPARE PARTS COMPLETION CA...

Page 8: ...hazardous chemicals must be labeled before being shipped to Hypro for service or warranty consideration Hypro reserves the right to request a Material Safety Data sheet from the Purchaser for any pum...

Reviews: