Hypro 3430-0635 Instructions Download Page 1

Fig. 4

Fig. 5

SEAL REPLACEMENT AND 

PUMP HOUSING ASSEMBLY
1. Install slinger ring on engine shaft.
2. Lubricate and install the o-ring around back side of

metal portion of the seal (See Figure 1). Insert the

stationary portion of the new mechanical seal by

carefully pushing only on the outer metal ring as

you press it into the casing cover. Use a tool with

1-1/2" ID, such as 1-1/2" diameter PVC pipe, 4"

long that fits over the carbon face of the seal, but

pushes only on the metal ring to insert the seal.

The carbon surface of the seal must be facing you

during installation.  Be careful to avoid scratching

the seal’s carbon surface. (See Figure 2.)

3. Apply medium strength (Blue) threadlocker onto

the (4) engine mounting bolts and install about (4)

turns into the engine. Install the pump flange by

sliding over the engine shaft 45 degrees clockwise

from the up position. Once the flange has mated to

the engine, rotate the flange 45 degees counter-

clockwise (CCW) to lock the flange into the slots.

Tighten the (4) mounting bolts with a 13mm

wrench to a torque of 10 foot pounds.

Note: Be sure to hold the pump flange in the “UP”

position when tightening bolts. This will ensure that

the pump bases will not be cocked off center in the

final assembly. (See Figure 3.)

4. Lubricate the seal cavity of the impeller with 

WD-40, LPS or equivalent, and carefully press the

seal’s mating ceramic ring in place, seating it

squarely on the bottom of the cavity. The glossy,

finished side of the ceramic seal must be facing

you.  IMPORTANT: Make sure both seal surfaces

are clean and lubricated. Never run seal surfaces

dry. (See Figure 4.)

5. Install the impeller onto the engine shaft using the

bolt, washer and seal. Bolt seal must not be worn.

Tighten the impeller bolt to 10 foot pounds. (See

Figure 5.)

6. Install diffuser onto the casing cover with three

Phillips-head screws.

7. Install the pump casing onto the casing cover and

o-ring, and secure with the 10 bolts, nuts and

washers, using a 10mm socket and wrench.

Torque the bolts to 45 inch pounds.

8. Once assembly is complete, pull on the engine

recoil starter with engine switch in the “OFF”

position to verify that the impeller rotates smoothly

without catching. Connect spark plug wire.

Assembly and inspection is now complete.