Maintenance
7
246
809480
Instruction Manual
XPR300
Estimate the total coolant volume for your cutting system
The capacity of the coolant reservoir for the XPR cutting system is 22.7 liters to 45.42 liters
(6 US gallons to 12 US gallons).
A cutting system with long leads requires more coolant than a cutting system with short leads.
To calculate the estimated total coolant volume necessary for your cutting system, use the
calculations below:
For total estimated volume in liters:
For total estimated volume in US gallons:
Replace all of the coolant
The use of old coolant can decrease coolant flow, which can cause higher torch temperatures that
shorten the life of consumable parts.
Hypertherm recommends that you replace all of the coolant at least once every 6 months, as part of
routine preventive maintenance. More frequent replacement can be necessary because of
environmental conditions including but not limited to contaminants in your coolant or diagnostic
codes that indicate coolant problems.
For instructions about preventive maintenance (such as weekly, monthly,
and yearly tasks) see the
XPR300 Preventative Maintenance Program
(PMP) Instruction Manual
(809490).
Adding new coolant to the reservoir when the coolant level is low is
not
the same as replacing all of
the coolant.
All
of the coolant must be removed in order to flush the coolant system.
The steps below describe how to remove all of the old coolant. Refill the cutting system with new
coolant only after you remove all of the old coolant.
For coolant installation steps, see
26
+
0.2534
X
Length of leads (
in meters
) between the
plasma power supply and gas connect
console for your cutting system
=
Total estimated volume (in liters)
6.8
+
0.0204
X
Length of leads (i
n feet
) between the
plasma power supply and gas connect
console for your cutting system
=
Total estimated volume (in
US gallons)
Summary of Contents for XPR300
Page 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Page 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Page 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Page 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Page 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Page 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Page 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Page 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Page 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Page 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Page 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Page 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Page 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Page 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Page 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Page 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Page 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...