Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC
Operator Manual
810470
43
Powermax85 SYNC
CSA configurations (1-phase)
CSA configurations (3-phase)
CE/CCC configurations (3-phase
)
Input voltage at 50 Hz/60 Hz*
200 V – 208 V 230 V – 240 V
480 V
Input current at rated output (85 A × 143 VDC = 12.2 kW)
70 A / 68 A
58 A
29 A
Input current during arc stretch
98 A
98 A
50 A
Fuse (time-delay)
100 A
100 A
50 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz*
200 V – 208 V 230 V – 240 V
400 V
480 V
600 V
Input current at rated output
(85 A × 143 VDC = 12.2 kW)
42 A / 40 A
35 A
21 A
18 A
17 A
Input current during arc stretch
60 A
60 A
38 A
31 A
30 A
Fuse (time-delay)
60 A
60 A
40 A
30 A
30 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz*
380 V
400 V
Input current at rated output (85 A × 143 VDC = 12.2 kW)
20.5 A
19.5 A
Input current during arc stretch
38 A
38 A
Fuse (time-delay)
40 A
40 A
* All models have a voltage tolerance of +10% / -15%.
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...