Do a check of the component positions and wire routing
1.
Make sure that all of the torch components are in the correct positions in the right side of the
torch shell. Compare the appearance of the torch components with the photograph you got on
, or with
Figure 12
– Full-length machine torch components in correct positions
2.
Make sure that the routing of all of the wires is correct, as shown.
Figure 13
– Wire routing in correct positions
2
1
3
4
5
3
2
1
RF torch PCB wires
2
Cap-sensor switch wires
3
Pilot arc wire
4
Torch-lock switch wires
5
RF wires